User's Manual

Title
Franklin Home Power User Manual
Date
August 10, 2021
Doc. No.
FD21081001
Revision
V01
© 2021. FranklinWH Technologies Co., Ltd. Page 18 Total 31
type
EPO EPO connection, NC type Reserved
DI1 Generator alarm, NO type Reserved
CAN IN Communication between aGate and
aPoewers
Loop-in wiring system.
If the loop is broken (2 CAN
cables are broken), the power
system will be off. Only 1 CAN
cable is broken, the system
works well.
CAN OUT
VCC IN 20VDC from aPower Loop-in wiring system
If the loop is broken (VCC
in/VCC out cables are all
broken), the system will power
off when the grid/solar is
off.
Otherwise, the system will work
well.
VCC OUT
DI2 NO type Reserved
DI3 NO type Reserved
DI4 NO type Reserved
Eth1 100M, Ethernet ports to the
home
gateway or VPP networks
Plug and play
Eth2
SIM card Support the U.S. and Canadian
standards GSM, WCDMA, CDMA EVDO,
CDMA2000, LTE (FDD), LTE (TDD),
Mobile network, cloud access
(alternate channel)
CT5,CT6, (J7) Grid CT connection
4G/WIFI 4G/WIFI connection
SMART RELAY Connect to smart circuit relay in
aGate
SOLAR RELAY Connect to the solar board in
aGate
RS485 Connect to AC meter in aGate
3.6 aGate optional
1) Optional generator circuit relay
The generator circuit connection is blanked by default. The
Figure Optional generator circuit relay