User's Manual

Title
Franklin Home Power User Manual
Date
August 10, 2021
Doc. No.
FD21081001
Revision
V01
© 2021. FranklinWH Technologies Co., Ltd. Page 20 Total 31
4 Datasheet
4.1 aPower datasheet
Table aPower datasheet
PERFORMANCE SPECIFICATION
COMPLIANCE INFORMATION
Battery Type
Lithium Iron Phosphate
(LFP)
Certificate
UL1973, UL9540, UL9540A, UN38.3, UL1741,
IEEE 1547, IEEE 1547.1, EMI Part 15, Class B
Usable Capacity 13.6kWh
1
Seismic ACI56, IEE693-2005 (High)
Aggregate Throughput 43MWh
2
Environmental
RoHS Directive 2011/EU
California Proposition 65
Coupling Type AC Coupling Emissions FCC Part 15 Class B
Rated Input/Output Voltage 120/240VAC split MECHANICAL SPECIFICATION
Feed-in Type Split phase Dimensions (H x W x D)
45.3in x 29.5in x 11.4in
1150mm x 750mm x 290mm
Connection Support L1/L2/N/PE Net Weight 386lbs. (175kg)
5
Grid Frequency 60Hz Volume 234L
Real Power, Maximum Continuous 5kW Mounting Wall mount or floor mount
Real Power, Peak(10s, off-grid/backup) 10kW (Discharge) ENVIRONMENTAL SPECIFICATION
Apparent Power, Max Continuous 5.8kVA Operating Temperature -4℉ to 122℉ (-20℃ to 50℃)
6
Apparent Power, Peak
(10s, off-grid/backup)
10kVA (Discharge)
Recommended
Temperature
32℉ to 86℉ (0℃ to 30℃)
Load Start Capacity 110A LRA Operating Humidity (RH) Up to 100% condensing
Maximum Supply Fault Current 10kA
Recommended Storage
Temperature
-4℉ to 86℉ (-20℃ to 30℃)
Up to 95%RH, non-condensing
Maximum Output Fault Current 42A Maximum Elevation 9843 feet (3000m)
Imbalance for Split-phase Loads 100% Environment Indoor or Outdoor
Power Factor Range (Full-rated Power) -0.85 to +0.85 Enclosure Type Type 3R
Round Trip Efficiency 86%
3, 4
Ingress Rating
IP67 (Battery and Power Converted
System)
IP56 (Wiring Compartment)
Inverter Topology Isolated
Warranty
12 years
Noise Level
<30dB(A) optimal,
<45dB(A) maximum
1. Measured at battery DC output at beginning of life
2. 70% EOL at warranty 12 years and measured at battery AC output.
3. At 25℃ (77℉) 2.5kW charge/discharge power
4. AC to battery to AC at beginning of life
5. The net weight doesn’t include the installation bracket.
6Performance will be derated when the operation temperature >45℃