© 2021. FranklinWH Technologies Co., Ltd. Page 21 Total 31
4.2 aGate datasheet
Table aGate datasheet
PERFORMANCE SPECIFICATION COMPLIANCE INFORMATION
AC Voltage (Nominal) 120/240VAC Certificate
UL1741 PCS, UL67
1
,
UL869A
1
, UL916
Feed-in Phase Split, L1/L2/N/PE Emission FCC Part 15 Class B
2
Grid Frequency 60Hz MECHANICAL SPECIFICATION
Overcurrent Protection Device 200A maximum Dimensions (H x W x D)
31.5in x 21.7in x 6.3in
(800mm x 550mm x 160mm)
Maximum Input Short Circuit Current 10kA Weight 48lbs. (22kg)
Overvoltage Category Category IV Mounting
Wall mount or
Semi-flush mount
AC Meter Accurate +/-1% ENVIRONMENTAL SPECIFICATION
Backup Transition <16ms Operation Temperature Range -4°Fto 122°F(-20℃to 50℃)
Connectivity Ethernet, WIFI, 4G Operating Humidity (RH)
Up to 95%RH,
no condensing
Work Modes
Self-Consumption
Load Shifting
Backup Standby
Emergency Backup
Maximum Elevation 9843 feet (3000m)
User Interface FranklinWH APP Environment Indoor and outdoor rated
Solar Input Protection Device 80A Max. Enclosure Type Type 3R
Genset Overcurrent Protection Device 200A Max. (Optional)
Smart Circuit Protection Device
(Optional)
1*80A Max.@240V
2*50A Max.@120V
Scalability Up to 15 aPowers
Warranty 12 years