Owner's manual

Link:
This enables the multi-channel link capability. Please note that is feature has to be turned on on all
participating units.
Sub-Menus:
There are three sub menus available to adjust the following parameters:
Meter: Output Meter adjustments
Utilities: Safe/Recall Parameters, Calibration etc.
Meter Sub Menu:
After selecting the meter menu on the main menu page the screen below will be displayed.
Meter Range:
The meter range of the peak meter can be switched between 60dB (one LED per dB) and
30dB (one LED per 0.5dB). In the 60dB setting the overall range is from -39dB to +20dB, in
the 30dB setting from -24.5dB to + 5dB.
Meter Hold :
The peak hold time can be selected between 0s, 2.5s and indefinitely. In the 0s setting no
peak hold is performed and in the indefinitely setting the user has to manually reset the hold
value by selecting a different hold time.
Fredenstein F660 Manual Release 2.1 July 18, 2014 Page 5