2 Operation
2.1 Installation Information
The Magnetic Field Generator with CAM is mounted on a vehicle or piece of machinery. The
Collision Avoidance Module is connected to the Generator via an interface header. Metal near
the Magnetic Field Generator may impact performance by reducing the field size. The CAM can
be blinded by a Xenon strobe light or a cab silencer if installed within 21 inches of the CAM.
After installing the Magnetic Field Generator/CAM on the machine, performance of the unit
should be verified by operation and test.
2.1.1 Inoperability Warning
The Magnetic Field Generator with CAM may experience erratic responses when in very close
proximity to some electronic devices. Electrical devices may transmit an electrical field and
noise from these fields may cause interference with the Magnetic Field Generator. A safe
guideline is to keep the Magnetic Field Generator at least 4in or 100mm away from any
electrical devices included but not limited to methane monitor, radio, mobile phone, GPS, PDA,
battery charger and laptop computers.
2.2 Charging
The Magnetic Field Generator/CAM is directly powered downstream when the ignition of the
vehicle is turned on and requires no charging.
2.3 Alerts
Magnetic Field Generators are designed to automatically adjust and maintain the original zone
size. If the truck supply voltage changes or changes occur resulting in a reduction of zone sizes,
the system will automatically adjust as much as 5% to ensure that the zones remain where they
were initially set. If the processor senses a significant power reduction, the alarm may sound for
a period of time. When the sounder is activated, power must be cycled to restore normal
operation. If the problem persists, then service is required.
The generator tolerates voltage fluctuations from 10-16V. A converter is needed for voltages
greater than 15V. If the processer switch (SW) on the PCB is in the OFF position, a continuous
alarm will sound at maximum dB.
2.4 Maintenance
The Magnetic Field Generator/CAM should be regularly cleaned to reduce buildup of dust and
dirt. The user should check to see if the LEDs are working before using the device.
2.5 Adjustments
Magnetic field size and Warning Module Volume are adjustments which are made on the
Magnetic Field Generator. To make the adjustments, remove the lid on the top housing. To