User's Manual

US7,420,471; US8,169,335; US8,232,888; US5,939,986;
US6,810,353; AU2005289704; ZA2007/02919; ZA2008/02673;
ZA2010/06816, ZA2010/09068 Patent Pending
o MFG Field Size Adjustment To adjust the field size of the MFG, the Range
Adjust Tool must be in the Danger Zone of the MFG magnetic field. Ideally this
location is approximately four feet from the MFG. Using the Range Adjust Tool
the magnetic field produced by the MFG is made larger by depressing the red-
colored button Similarly, field size is made smaller by depressing the black-
colored button.
A clicking sound is emitted from the Range Adjust Tool each time a button is
depressed. This is an indication that an adjustment signal is being sent to the
MFG. If a button is depressed and held longer, clicking sounds increase in
frequency and the speed that the field-size increases or decreases speeds up.
A HIT-NOT® Personal Alarm Device (PAD) should be used to measure the MFG
magnetic field size and determine when the desired field size is achieved.
1.2 Frequency of Operation
The Range Adjust Tool receives on a frequency of 73 kHz and transmits at 916.48 MHz.
1.3 Label Information
The Range Adjust Tool label is located on the top housing opposite of the battery-access side.
Range Adjust Tool Label
3