User Manual

Rev: 29 April 2005
3.2.2 Page scan
When page scan is enabled, the Endpoint unit is connectable for other Bluetooth units on page.
The Page scan interval parameter defines the amount of time between consecutive page scans. This is
defined as the time interval from when the device started its last page scans until it begins the next page
scan.
The Page scan window parameter defines the amount of time for the duration of the page scan. The Page
scan window can only be less than or equal to the page scan interval.
By choosing a long interval time and a short window time the average current consumption can be
decreased at the cost of slow response time on page.
By choosing a short interval time and a long window time faster response time on page can be obtained at
the cost of increased average current consumption.
The inquiry and page scan parameters have a span of 11.25ms – 2.56s.