Sanitization and Re-Use
The TL01R monitoring device will be removed by cutting the one-time use strap from the
offender leg
Collection
Place the TL01Rand strap into a clean plastic bag and return them to the vehicle for inspection
and cleaning.
Inspection
The TL01R monitoring device should be inspected for signs of damage, units with damage
should be dealt with in accordance with local protocols. Damage includes any significant surface
marking which may be indicative of the unit being exposed to high impacts or tampering. Special
care should be taken to ensure the following areas are inspected;
Any seam between plastic casings, damage here may indicate the sealing surfaces of the unit
are damaged.
The inside surfaces of the strap acceptance area. The unit should be returned for testing if
there is any sign of wear in this area.
Cleaning
If there is any heavy soiling or biological matter on the unit that is unlikely to be easily removed
by a sanitizing wipe, then the unit should be cleaned thoroughly in line with local protocol.
To sanitize a TL01R in the field the following process should be followed;
Wear gloves.
Using the removal tool, release the TL01R from the Strap and remove the locking plates.
Wrap the unit in an approved sanitizing wipe.
Rub the unit vigorously with the wipe ensuring all surfaces receive a good covering of alcohol.
Wrap the unit in a new wipe and place in a sealed plastic bag for at least one minute.
Remove the unit from the bag, dispose of the wipe and allow the unit to dry in a well-
ventilated area.