User Manual
102| AIRCRAFT FLIGHT MANUAL
BATTERY EXHAUSTION
If battery cell voltage is below Alarm Voltage (all flight modes)
1. Status Light ILLUMINATES RED (solid or blinking)
2. Orientation Lights FLASH
3. ALTA 6 LAND as soon as possible
If battery cell voltage is below Land Voltage while flying in Manual Mode
1. Status Light FLASH RED
2. Orientation Lights FLASH
3. ALTA 6 LAND as soon as possible
(Autoland is not initiated)
If battery cell voltage is below Land Voltage while flying in Height or Position Mode
1. Status Light ILLUMINATES RED (solid or blinking)
2. Orientation Lights FLASH
3. ALTA 6 AUTOLAND is initiated automatically
4. Pitch and Roll MANEUVER away from people or objects
AMPLIFICATION
If the battery cell voltage drops below the Alarm Voltage, the Status Light will
turn solid red in Manual Mode or flash red if in Height Hold or Position Hold. The
orientation lights will flash in the user-defined colors. If all orientation lights have
been specified off, the orientation lights will flash red. Terminate the flight and land
as soon as possible.
If the battery cell voltage drops below the Land Voltage, the Status Light will flash
red. The orientation lights will flash as described above. In Manual Mode, the pilot
will remain in full control of the ALTA. In Height or Position Mode, ALTA will begin
to Autoland, and pitch and roll commands will remain active. During the time ALTA
is descending, use pitch and roll to avoid people and objects during the descent and
landing.
WARNING
ALTA 6 will not Autoland if it is in Manual Mode. Full throttle
authority is available to the pilot in a battery exhaustion event.