Installation & Assembly

Finished Height
(Concrete to Top of Drum)
Drum Installed
5" into Concrete
(3" or Less)
(9" or Greater)
6" Thick Concrete Pad
Parts List:
Step 1:
Arrange Drums in desired location and pattern. Drums can be laid out in any configuration desirable, but must be installed less
than 3" or greater than 9" apart.
WARNING: Between 3" and 9" there lies a chance for a child's head to get stuck.
(Reference: US Consumer Product Safety Commission, Public Playground Safety Handbook)
Step 2:
Determine border of trench for concrete pad. Trench should be a minimum of 6" deep. Concrete pad should perform under
local soil and weather conditions.
Step 3:
Excavate trench to required depth. Check levelness of trench then pour concrete and fill trench completely per code
requirements. Immediately after the concrete has been poured, drive the Tuned Drums into the wet concrete per your
chosen layout.
Step 4:
The bottom edge of the Drum Bases are scalloped to assist in their installation into the concrete. Twist Drums into concrete to a
depth of 5". Check for plumbness, if needed brace the Drums to keep them rigid and in place during the curing process.
Leave to set according to the concretemanufacturer's guidelines.
Step 5:
Check for sufficient clearance around instruments. A 36" clearance is recommended around the the entire Drum arrangement
for wheelchair accessibility, however this is not required for proper function. Drums may also be installed next to a wall or in a
variety of different configurations.
Step 6:
Remove plastic film from drum caps if applicable.
ITEM NO.
DESCRIPTION
QTY.
NORMAL FINISHED HEIGHT
TODDLER FINISHED HEIGHT
1
15" In Ground Tuned Drum
1
37" 29"
2
12" In Ground Tuned Drum
1
35"
27.5"
3
10" In Ground Tuned Drum
1
33" 26"
4
8" In Ground Tuned Drum
1
31"
24.5"
5
6" In Ground Tuned Drum
1
29" 23"
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
FREENOTES HARMONY PARK. ANY
REPRODUCTION IN PART OR AS A
WHOLE WITHOUT THE WRITTEN
PERMISSION OF FREENOTES HARMONY
PARK IS PROHIBITED.
FREENOTES HARMONY PARK
194 BODO DRIVE, UNIT F
DURANGO CO 81303
TEL: (970) 375-7825
FAX: (970) 247-0856
WWW.FREENOTESHARMONYPARK.COM
SHEET 2 OF 3
TITLE:
SCALE: 1:16
REVISION: A
DATE: 2/9/2018
DWG. NO.
In Ground Installation with Parts List
TD-INSTALL