802.15.4 Output power -30 0 +2 dBm Over range of Pout from IC control in 2 dB
steps.
Note: On channel 26, output power should
not exceed -5 dBm (power setting
0x0E) to meet FCC Part 15
requirements.
Harmonics
2
nd
harmonics
3
rd
harmonics
-30
-30
dBm
dBm
Harmonics are compliant to ETSI and FCC
regulatory approval standards
RF Receiver
802.15.4 sensitivity -92 -95 dBm <1% PER for 20-byte packets
Proprietary high-speed sensitivity -80 dBm <1% PER for a minimum data payload of
400 packets
Regulatory Approval
FCC Product is approved accordingly to the FCC
part 15 standard
CE (ETSI) Product is approved accordingly to the EN
300 328 V1.7.1 (2006-10) standard
CE (EMC) Product is approved accordingly to the EN
301 489-1 V1.6.1 (2005-09) and EN 301
489-17 V1.2.1 (2002-08) standards
Safety
UL Product is approved accordingly to the IEC
60950-1 and EN 60950-1, First Edition
standards
Environment
RoHS Product complies with the EU Directive
2002/95/EC of 27 January 2003
WEEE Product complies with the EU Directive
2002/95/EC of 27 January 2003
Table 2-1. 1322x Network Node Specifications
Parameter Units Notes/Conditions