User manual

Memory Controller
MPC8260 PowerQUICC II Family Reference Manual, Rev. 2
11-30 Freescale Semiconductor
11.3.8 60x Bus-Assigned UPM Refresh Timer (PURT)
The 60x bus assigned UPM refresh timer register (PURT) is shown in Figure 11-14.
Table 11-13 describes PURT fields.
11.3.9 Local Bus-Assigned UPM Refresh Timer (LURT)
The local bus assigned UPM refresh timer register (LURT) is shown in Figure 11-15.
Table 11-14 describes LURT fields.
Table 11-12. MAR Field Description
Bits Name Description
0–31 A Memory address. The memory address register can be output to the address lines under control of
the AMX bits in the UPM
0 7
Field PURT
Reset 0000_0000
R/W R/W
Addr 0x0x10198
Figure 11-14. 60x Bus-Assigned UPM Refresh Timer (PURT)
Table 11-13. 60x Bus-Assigned UPM Refresh Timer (PURT)
Bits Name Description
0–7 PURT Refresh timer period. Determines the timer period according to the following equation:
This timer generates a refresh request for all valid banks that selected a UPM machine assigned to
the 60x bus (M
x
MR[BSEL] = 0) and is refresh-enabled (M
x
MR[RFEN] = 1). Each time the timer
expires, a qualified bank generates a refresh request using the selected UPM. The qualified banks
are rotating their requests.
Example: For a 25-MHz system clock and a required service rate of 15.6 µs, given
MPTPR[PTP] = 31, the PURT value should be 11decimal. (12*32)/25 MHz = 15.36 µs, which is less
than the required service period of 15.6 µs.
0 7
Field LURT
Reset 0000_0000
R/W R/W
Addr 0x0x101A0
Figure 11-15. Local Bus-Assigned UPM Refresh Timer (LURT)
T
imerPeriod
PURT 1+()MPTPR PTP[]1+()×
Bus Frequency
----------------------------------------------------------------------------------------
⎝⎠
⎛⎞
=