User's Manual

Spread Spectrum Wireless Data Transceiver User Manual
Preliminary GXM Manual Version 0.2 15
PRELIMINARY
8. To connect HyperTerminal to the transceiver, briefly short Pin 2 of the I/O port on the FreeWave
transceiver to ground. If connected to the diagnostics pins, type U (Capital ‘U’) to invoke the
Setup menu.
When Setup is invoked, the FreeWave Setup Main Menu will display in the HyperTerminal dialog
box. All three LED’s on the transceiver will light green
and stay green as long as the
transceiver is in the Setup mode.
9. Save the HyperTerminal connection settings by selecting Save from the File menu.
IMPORTANT NOTE: Whenever a change is made to the HyperTerminal settings in an open terminal
session, the connection must be disconnected then reconnected before the
settings will take effect.
Connecting and Disconnecting from HyperTerminal
The HyperTerminal dialog box displays several icons in the toolbar. To reconnect to HyperTerminal, click
on the Disconnect
icon, and then click on the Call icon to reconnect. If the settings have not
been saved they must be reselected when HyperTerminal reconnects to the transceiver.