Reference Manual

Table Of Contents
2. Basic Radio Programming and Setup
FGR3
User-Reference Manual
LUM0110AA Rev Jan-2019 Page 36 of 143 Copyright © 2019FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
2.2.2. Data Parity
Data Parity
Setting Description
Default Setting 0 (8, N, 1)
Options See Description.
Terminal Menu (1) Set Baud Rate > (A) Data Parity
Description: l Six data word length and parity configurations are available for use with
FreeWave radios.
l The default setting is 8-None-1 and is the most commonly used serial
communications protocol.
This table describes each option:
Option Data Bits Parity Stop Bits
0 8 None 1
1 7 Even 1
2 7 Odd 1
3 8 None 2
4 8 Even 1
5 8 Odd 1
2.2.3. Flow Control
Flow Control
Setting Description
Default Setting (0) None
Options l (0) None - No flow control CTS is active and de-asserts when buffering is 98%
full. Can pass XON/XOFF data but does not use it in any way.
l (1) RTS - Uses RTS/CTS (Request to Send/Clear to Send) for flow control.
l CTS performs the same way as in option (0) None.
l RTS must be activated for the radio to output data over the serial port.
l (2) DTR - Uses DTR/DSR (Data Terminal Ready/Data Set Ready) for flow
control.
l (3) DOT - Half Duplex.
Terminal Menu (1) Set Baud Rate > (F) FlowControl