Reference Manual

Table Of Contents
2. Basic Radio Programming and Setup
FGR3
User-Reference Manual
LUM0110AA Rev Jan-2019 Page 61 of 143 Copyright © 2019FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
Transmit Rate
Setting Description
Options l 0 - Diagnostics
l 1 - Normal
Terminal Menu (3) Edit TransmissionCharacteristics > (3) Xmit Rate
Description: FGR3 radios have two available Transmit Rate settings.
l The setting for normal operation of the radio is 1.
l When set to 0, the radios transmit back and forth continuously regardless if
they have any actual data.
l 0 should be used only as a diagnostic tool and not for normal operation.
l The strength of the signal may be gauged by the Clear to Send (CTS) LED.
l A solid red ( ) CTS LED indicates a strong signal.
l A blinking ( ) CTS LED indicates a weaker signal.
0 is useful to qualitatively gauge signal strength in Point-to-Point mode.