3. Configuring Point-to-MultiPoint Networks
FGR3
User-Reference Manual
LUM0110AA Rev Jan-2019 Page 87 of 143 Copyright © 2019FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
To help identify the radios in the network when running Network Diagnostics, set the Radio
Name and Radio ID fields on the MultiPoint Parameters tab.
The diagnostic program must be run from the Master radio. Diagnostics require:
l A setting between 1 and 128 in the Diagnostics parameter available in the MultiPoint
Parameters menu on the Master.
l A second computer or serial connection to run the diagnostics software.
l A diagnostics cable. (Available from FreeWave.)
l Diagnostics software. (Available from www.freewave.com).
Note: For more information about diagnostics, contact FreeWave Technical Support.
Contact FreeWave Technical Support (on page 8) for assistance.
Procedure
1. Connect the Master to the computer running Tool Suite.
2. Open Tool Suite.
3. On the Applications tab, click Network Diagnostics.
4. In the Networks section of the ribbon, use the list box to select the serial network to run
diagnostics on.
If there is no network defined, click Add and follow the instructions in the wizard.
5. On the ribbon, click Start.
6. To stop running diagnostics, click Stop.
Note: The Network Diagnostics application continues to poll for diagnostic data until it is stopped.
Important!: Tool Suite is NOT optimized for the collection and management of large amounts of
diagnostic data from continuous polling.
Collection of excessive amounts of data results in overall performance degradation in Tool Suite
and network throughput degradation.