Reference Manual
Table Of Contents
- Preface
- 1. Introduction
- 2. Basic Radio Programming and Setup
- 2.1. Setting the Radio's Role in the Network and the Network Type
- 2.2. Establishing Communication with Instrumentation and Computers
- 2.3. Establishing Communication with Other Radios in the Network
- 2.4. Designate the RF Transmission Characteristics
- 2.4.1. 900MHz Channel Select Parameters
- 2.4.2. 900MHz Frequency Key (Golden Setting)
- 2.4.3. 900MHz Frequency Zones
- 2.4.4. High Noise
- 2.4.5. 900MHz Hop Frequency Offset
- 2.4.6. 900MHz Hop Table Size
- 2.4.7. 900MHz Hop Table Version
- 2.4.8. Max Packet Size and Min Packet Size (Golden Setting)
- 2.4.9. MCU Speed
- 2.4.10. Remote LED
- 2.4.11. Retry Time Out
- 2.4.12. RF Data Rate (Golden Setting)
- 2.4.13. RTS to CTS
- 2.4.14. Slave Security
- 2.4.15. Transmit Power
- 2.4.16. Transmit Rate
- 3. Configuring Point-to-MultiPoint Networks
- 3.1. Point to MultiPoint Network Characteristics
- 3.2. Point-to-MultiPoint Network Quick Start
- 3.3. Point-to-MultiPoint Operation LEDs
- 3.4. Overlapping MultiPoint Networks
- 3.5. Establishing Communication with Other Radios in a MultiPoint Network
- 3.6. Routing Communications through the Network
- 3.7. Setting Other MultiPoint Parameters
- 3.7.1. 1 PPS Enable Delay
- 3.7.2. Diagnostics
- 3.7.3. DTR Connect
- 3.7.4. Local Mode
- 3.7.5. Master Packet Repeat
- 3.7.6. Master Packet Repeat in MultiPoint Networks with Repeaters
- 3.7.7. Max Slave Retry
- 3.7.8. Radio ID
- 3.7.9. Radio Name
- 3.7.10. Repeaters
- 3.7.11. Repeater Frequency
- 3.7.12. Retry Odds
- 3.7.13. Slave / Repeater
- 3.8. Conserving Power
- 3.9. Reading Diagnostics in Tool Suite
- 4. Configuring Point-to-Point Networks
- 5. Advanced Programming
- 6. Viewing Radio Statistics
- 7. Approved Antennas
- 8. FGR3 Wireless Data Radios Pinouts
- 9. Troubleshooting
- 10. FGR3 Release Notes
- Appendix A: FGR3 Technical Specifications
- Appendix B: FGR3 Board Level Mechanical Drawing
- Appendix C: 900MHz Factory Default Settings
- Appendix D: 900MHz Channel Frequency IDs
- Appendix E: FreeWave Legal Information
4. Configuring Point-to-Point Networks
FGR3
User-Reference Manual
LUM0110AA Rev Jan-2019 Page 91 of 143 Copyright © 2019FreeWave
This document is subject to change without notice. This document is the property of FreeWave Technologies, Inc.
and contains proprietary information owned by FreeWave. This document cannot be reproduced in whole or in
part by any means without written permission from FreeWave Technologies, Inc.
14. Enter the Slave serial number in the Master’s Call Book.
15. Enter the Master’s Serial number in the Slave’s Call Book or
disable the Slave Security (on page 59) parameter in the Slave.
Note: For more information about setting up the Call Book see Using the Call Book in Point-
to-Point Networks (on page 93).
16. On the Main Menu, type 3 and press <Enter>.
17.
18. Press <3> on the Main menu.
19. Set these parameters so they are identical on all radios in the network:
l Frequency Key
l Max Packet Size
l Min Packet Size
l RF Data Rate
Note: The Frequency Key option is located in the F submenu after you press <0> to access
the Frequency Key menu on Main menu <3>.
20. Press <Esc> to return to the Main menu.
Shortly after both radios are plugged in, they should establish a link with each other and the
connection is complete.
21. Using the Point-to-Point Operation LEDs (on page 92), verify that the radios are operating
as expected.