Hatch Sensor Unit Installation Instructions April 14, 2020 TrinityRail 2525 North Stemmons Freeway Dallas, TX 75207 1(800)227-8844
Hatch Sensor Unit TRHT-01 TABLE OF CONTENTS Safety Information .........................................................................................................................................................2 Functional Description ...................................................................................................................................................2 Warning Label ............................................................................................................
Hatch Sensor Unit TRHT-01 SAFETY INFORMATION * IMPORTANT SAFETY INSTRUCTIONS * Do not drop the device. Do not open the device. Do not expose device to conditions other than those in the “Technical Data” section. The ultrasonic transducer case is made from anodized aluminum, because of the material used there is a risk for spark if the transducer is impacted. Avoid impact or friction of any type to the Ultrasonic transducer. Warning: Device contains a Lithium battery.
Hatch Sensor Unit TRHT-01 WARNING LABEL Due to the specific plastic used in the product enclosure, it may be possible for an Electrostatic Discharge to occur if improper handling of the device is performed. The warning (“Electrostatic Discharge hazard”) informs the users to read the following instructions before performing any installation or maintenance related task. Installation and maintenance shall only be limited to NON hazardous locations.
Hatch Sensor Unit TRHT-01 INSTALLATION INSTRUCTIONS HATCH SENSOR UNIT Enclosure Cover Installation Wedge Pressure Sensor Cable Connector Ultrasonic Transducer Protective Cover Figure 1: Parts of the Hatch Sensor Unit Hatch Cover Latch Installed Hatch Sensor Unit Hatch Cover Hinge Cross-bar Member Figure 2: Installed Hatch Sensor Unit and Parts of the Hatch Cover TRHT-01 Hatch Sensor Unit Installation Instruction v 1-23.docx 04.14.
Hatch Sensor Unit TRHT-01 HATCH SENSOR UNIT INSTALLATION TO HATCH COVER 1. 2. 3. 4. 5. Remove the Center Pellet Screen from the Hatch Cover. Apply adhesive onto the cleaned area of the Hatch Cover that the Hatch Sensor Unit will attach to. Attach the Hatch Sensor Unit onto the adhesive, as seen in Figure 2, with the distance sensor housing closest to the center line of the vented hatch cover and facing towards the hinge of the Hatch Cover.
Hatch Sensor Unit TRHT-01 1. 2. Remove the Hatch Cover Seal. Position the Pressure Sensor Pad in the pocket to the right of the Hatch Cover Latch, as shown in Figure 3, and identify the mechanical securing locations. Secure pressure sensor pad in position mechanically. Intermediate Connector Figure 4: Sensor Pad to Hatch Sensor Unit Cable Connection 3. 4. 5. 6. 7. 8. Disconnect the Intermediate cable connection on the Pressure Sensor Pad. Secure the Pressure Sensor Pad to the Hatch Cover mechanically.
Hatch Sensor Unit TRHT-01 HATCH SENSOR UNIT COMMISSIONING Please reference the TrinityRail mobile pairing application for instructions on commissioning the Hatch Sensor Unit with the gateway. MULTIPLE HATCH SENSOR UNIT COMMISSIONING Please reference the TrinityRail mobile pairing application for instructions on commissioning multiple Hatch Sensor Units with the gateway. MAINTENANCE INSTRUCTIONS This product does not require maintenance. It is not possible to replace the battery in the field.
Hatch Sensor Unit TRHT-01 TECHNICAL DATA Product ID TrinityRail Hatch Sensor Unit (TRHT-01) TRHT-01 Physical Size Weight 9.0in x 5.0in x 5.0in (LWH) 27.9 oz. (790g) Environmental Operating Temperature Hazardous Location Temperature -22˚F to 176˚F (-30˚C to 80˚C) -22˚F to 140˚F (-30˚C to 60˚C) Energy Battery Type Nominal Battery Voltage Size Targeted Battery Life Bluetooth 5.1 Lithium Thionyl Chloride 3.6V D cell, quantity = 3 6+ years 2.400 to 2.
Hatch Sensor Unit TRHT-01 CERTIFICATIONS Hazardous Locations: Intrinsic Safety ia (UL 913 5th Ed, UL 61010, & CSA 22.2 No. 60079-0 and 60079-11, Class I, II, III / Division 1 / Zone 0/ Groups A-G / T4) Environmental: UL IP65 Communication: FCC, IC, NOM Bluetooth Sig, IFETEL FCC Statement Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Hatch Sensor Unit TRHT-01 REVISION HISTORY Revision A Revision Date Description of Change 4.22.2020 Initial Release TRHT-01 Hatch Sensor Unit Installation Instruction v 1-23.docx 04.14.