FMC012430/013030/013630/014830 ® MEDICINE CABINET INSTALLATION GUIDE FRESCOES IMPORTANT SAFETY INSTRUCTIONS When using an electrical furnishing, basic precautions should always be followed, including the following: | READ AND FOLLOW ALL DANGER | INSTRUCTIONS BEFORE | USING THIS CABINET. WARNING To reduce the risk of burns, fire, electric shock or injury to persons. Use this furnishing only for its Intended use as described in these instructions. Do not use attachments not recommended by the manufacturer.
FMC012430/013030/013630/014830 ® MEDICINE CABINET INSTALLATION GUIDE FRESCOES TOOLS REQUIRED FOR ASSEMBLY FA 1/8" Drill Bit Single ) Double Door iy Door Cabinet .
FMC012430/013030/013630/014830 ® MEDICINE CABINET INSTALLATION GUIDE FRESCOES Bgl ey A Cabinet's width B Cabinet's Height € Cabinet's Depth A NOTE: Determine overall medicine cabinet dimensions. If recessing medicine cabinet, determine rough-in dimensions. LY 5* 5" 22.5" x 28.4" 28.4" x 28.4" | 34.3" x 28.4" 46.1" x 28.4" "MOTE: All dimensions & specifications are approximate and subject to change without notice.
PRIOR TO MOUNTING: ILLUSTRATION 24 © FMC012430/013030/013630/014830 | INSTALLATION GUIDE #2018 FRESCA™ All rights reserved, This material may not be reproduced, displayed, modified or distributed without the express prior written permission of the copyright holder.
FMC012430/013030/013630/014830 ® MEDICINE CABINET INSTALLATION GUIDE FRESCOES ELECTRIC CONNECTIONS ALL WIRING SHOULD BE DONE BY A QUALIFIED LICENSED ELECTRICIAN WARNING: shut off power before wiring the cabinet.
Draw the perimeter of the medicine cabinet on the wall: RECESS-MOUNT INSTALLATION Cut the marked perimeter with appropriate tool, Level, then secure the medicine cabinet with the screws through the mounting holes into the framing studs. Frame the cutout opening: (See illustration below) Place and hold the: medicine cabinet in the cutout opening. 4 STEPS TO FRAME THE CUTOUT OPENING Choose the position for your shelves, then push and twist the snap-in pins into place. &.
SURFACE-MOUNT INSTALLATION Level and mark tha medicine cabinets location on the wall from paint a to point. IMPORTANT: Bottom mounting brackets mist be attached to furring straightener or wall studs, Attach bottom Level and mark. bracket (E) to Insert top mounting bracket (DY into the top of the cabinet {A}. With assistance, rest the medicine cabinet {A} on the bottom mounting bracket {E3 and hold it in place. IMPORTANT: Top mounting brackets must be attached to furring strip/channel or wall studs.
SURFACE-MOUNT INSTALLATION NOTE: For more details on the shelf ey 2 installation please refer to Page 5, Step Connect the glass shelves to the cabinet by pushing the side of the shelf in the left or right clip and snapping the shelf down. IMPORTANT: Top mounting brackets Slide top brackets into chains! Make sure top brackets are must be attached to furring at the top of the cabinet. locked in the grooves. strip/channel or wall studs.
Plug the door into the cabinet. Az. Insert clear snap in shelf Shs, Push the side of the shelf Je. insert clear plugs (4) into the clips (F) into holes on the in the left or right clip and remaining or unused holes, then cover sides of the cabinet snap the shelf (C) down. screw heads with the screw cups (8).
How to use Defogger Switch and Dimmer Switch: Touch the Defogger switch to turn the heating coils on or off. Touch the Dimmer switch to turn the task light on or off. Press and hold the dimmer switch to dim or brighten the task lights. Dimmer switch stores the current light level intensity when switched off and on. How to set our digital clock: Press and hold the button on the side of the door for two seconds to enter programming mode.