Install Instructions
WARNING
WARNING
Align Flanges
A
APCO MAG Unit
B
APCO MAG 11 UV Lamp 1 Year*
C
APCO MAG 11 UV Lamp 2 Year*
D
APCO MAG 15 UV Lamp 1 Year*
E
APCO MAG 15 UV Lamp 2 Year*
F
ER Power Supply*
G
ST/DT Power Supply*
H
SI/DI Power Supply*
I
Self-tapping Screws
J
Quick Nut (plastic)
K
Spade Connector
L
Tap-in Connector
M
“Z” Mounting Bracket
N
Sight Glass
O
Warning Sticker
The APCO MAG is installed in the central air system to reduce
odors and airborne biological contaminants for improved
indoor air quality. The APCO MAG also reduces microbial
growth within the air system.
Important: some materials inside the air system (including lter media, ex duct, wiring etc.)
may not be UV light resistant. Use the optional UV shield (part #TUV-SHIELD-LPC) or cover the
materials with reective tape.
Air Handler
2nd UV Lamp
2
Installation Notes
The APCO MAG is usually installed inside the central
air handling system. The unit should be oriented so
that the air ows past the UV Light rst then into
the Matrix Element but a reversed installation is
permitted if mounting on the return-side of the coil.
If a second optional UV lamp is used (APCO MAG
Dual) select a location inside the air system that
will allow it to shine on the greatest surface area or
the area with the most evident microbial growth.
To install the secondary UV light use the Optional
2nd Remote UV Light Installation Instructions
provided with APCO MAG Dual.
Typical installations include:
A
APCO MAG single in air handler
B
APCO MAG dual in air handler
C
APCO MAG in Package Unit
A B
Package Unit
C
A
O
NM
K
L
J
I
H
F
G
D
E
1
Parts List
Note: These parts
are only included
with APCO MAG Dual.
*Note: only one lamp and power supply are included with APCO MAG.
B
TUVL-111P
C
TUVL-211P
D
TUVL-115P
E
TUVL-215P
TUVL-115P
TUVL-215P
3
Mount Lamp
Mount the UV Lamp to the APCO
MAG unit as shown using 2 quick
nuts
J
.
J
TUV-APCO-MAG-MAN 031020
US patent #7,704,463
IMPORTANT!
• Only qualified technicians should install this product
• Install in accordance with relevant building codes
• Read instructions carefully including safety warnings
4
Air Handler Interior
Surface Installation
1.
Determine the optimal position for
placement of APCO MAG inside the air
system.
2. Use a utility knife to cut a slit in the
insulation on the interior surface.
3. Place the magnetic mounting bracket
directly on the metal surface or remove the
magnet and hard-mount the bracket using
the self-tapping screws provided. Use foil
tape to close the cut in the insulation.
2.
3.
Important! do not install the mounting
magnet within 12” of digital signal
devices as this may cause interference
.
6
UV Lamp Connection
Make sure the anges are aligned and then push
the connectors rmly together. A tight connection
ensures a proper water-resistant seal.
2.
1.
7
Lamp Replacement
The germicidal UV lamp in APCO needs to be replaced
periodically. TUVL-111P and TUVL115P lamps should be
replaced every year. TUVL-211P and TUVL-215P should be
replaced every 2 years.
Note: UV lamps will continue to emit visible light but lose
germicidal eectiveness over time. You can upgrade to a 2
year lamp with your existing APCO system.
CAUTION!
UV lamps contain small amounts of mercury - dispose of lamps in accordance with local
environmental regulations. For more information visit www.lamprecycle.org
Note: Use of replacement UV lamps other than Fresh-Aire UV® voids warranty.
IMPORTANT!
Systems with high 24 VAC loads may require the installation of a separate 24 VAC
transformer to power the UV light.
Always use a separate 24 VAC transformer with “communicating” air systems.
Draws 16 VA, may need to do load calculation: Volts under load X Amps under load.
B
TUVL-111P
C
TUVL-211P
D
TUVL-115P
E
TUVL-215P
Replacement lamps for
TUV-APCO-MAG15
Replacement lamps for
TUV-APCO-MAG11
*Installation of this product by anyone other than licensed HVAC or electrical contractors voids warranty.
Manufacturer’s Warranty:
This warranty supersedes and replaces any warranty statements orally made by the Sales Person, Distributor or Dealer or contained in the written instructions or other
Brochures or informational documents in relation to this product. This warranty gives you specic legal rights, and you may also have other rights which vary from
State to State.
What Does This Warranty Cover? This lifetime limited manufacturer warranty covers any defects or malfunctions in material and workmanship under the normal use
and service when operated and maintained in strict accordance with manufacturer’s instructions for the Lifetime of the equipment.
How Long Does The Coverage Last? 1) Power Supply: For as long as you own the real property where the product is installed. 2) TUVL-1XX Series Ultraviolet Lamp
is warranted for germicidal output for one-year from the date of installation. 3) TUVL-2XX Series Ultraviolet Lamp is warranted for germicidal output for two (2) years
from the date of installation. This warranty is not transferable.
What Will Triatomic Environmental, Inc. Do? Triatomic Environmental, Inc. will replace any defective or malfunctioning part at no charge. You must pay any labor
charges and shipping charges of defective product to our warranty department.
What Does This Warranty Not Cover? THIS PRODUCT IS NOT INTENDED TO BE PURCHASED AND INSTALLED BY UNLICENSED HVAC OR ELECTRICAL CONTRACTORS. This
warranty does not cover products or parts purchased from any source other than licensed HVAC or electrical contractors. This warranty does not cover parts installed
by unlicensed HVAC or electrical contractors. This warranty does not cover parts damaged as a result of misuse, abuse, or any use other than its intended use, accident,
acts of god, neglect, or from improper operation, maintenance, installation, modication or adjustments. Triatomic Environmental, Inc. shall have no responsibility for
charges incurred by the customer for installation or removal of warranted items.
This warranty does not cover parts or equipment used with the Fresh-Aire UV system that are not manufactured by Triatomic Environmental, Inc.
**This warranty shall be void if UV lamps from manufacturer’s other than Triatomic Environmental, Inc. are used with this equipment.
Consequential and incidental damages are not recoverable under this warranty. Manufacturer assumes no liability for any harm, which may occur as a result of the
use of the equipment herein and shall not be liable for consequential or any other damages whether or not caused by manufacturer’s negligence or resulting from any
express or implied warranty or breach thereof. Consequential damages for the purpose of this warranty shall include, but not be limited to, loss of use, income or
prot, or loss of or damages to property or injury or death to persons or animals occasioned by or arising out of operation, use, the operation, installation, repair or
replacement of the equipment or otherwise. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
There are no Warranties which extend beyond the description of the face hereof.
How Do You Get Service? In order to be eligible for service under this warranty you MUST return the warranty registration card or register online at www.freshaireuv.
com. If something is wrong with your product, call your installing contractor to receive a Return Merchandise Authorization (RMA) and instructions for returning the
product to a licensed distributor in your area or the manufacturer.
Once the product is returned, we will inspect your product and contact you within 10 business days of our receipt of the product to give the results of our inspection. If
we determine that the product is covered under this warranty, we will ship to you at no additional cost a replacement part. Replacement parts may be refurbished. If we
determine that the product is not covered under this warranty, or that this warranty is void, the product will be returned to you COD. There is no charge for inspection.
How Does State Law Apply? This warranty gives you specic legal rights, and you may also have other rights which vary from state to state.
WARNING
PROTECT EYES FROM UV LIGHT
TURN OFF UNIT OR DISCONNECT
BEFORE SERVICING
5
Connecting to Power
IMPORTANT
Before connecting to power conrm which APCO MAG model is being installed. Turn o main
power source before installation. Model information is printed on the Power Unit cover.
IMPORTANT! Must be wired to constant power - do not connect to blower relay.
APCOMAG ER
APCOMAG
SI/DI
ST/DT
120-277 VAC
POWER SUPPLY
UV LAMP
4 PIN
CONNECTOR
L1 - BLACK
L2 or N - WHITE
GND - GREEN
Optional 2nd UV Lamp
24 VAC
POWER SUPPLY
UV LAMP
BLACK
4 PIN
CONNECTOR
RED
24 VAC TRANSFORMER
COMMON / BLUE
HOT / RED