Install Instructions

120-277 VAC
POWER SUPPLY
UV LAMP
BLUE CABLE
DISCONNECT
L1-BLACK
L 2 or N- WHITE
GND- GREEN
8
Lamp Replacement
The germicidal UV lamp in Blue-Tube UV® needs to be replaced periodically. TUVL-115P
and TUVL-115P-OS (odor control) lamps should be replaced every year. TUVL-215P and
TUVL-215P-OS should be replaced every 2 years. Note: UV lamps will continue to emit
visible light but lose germicidal eectiveness over time. You can upgrade to a 2 year and/
or odor control lamp with your existing power supply.
Align Flanges
5
Power Supply Installation
IMPORTANT! Check which power supply is
included with your Blue-Tube UV® before
connecting to power. Turn o main power
source before installation.
1. Find a suitable location for the power supply
inside the control panel of the air handler.
Install using the self-tapping screws.
2. Use the wiring diagrams below to connect to
power. The low voltage power supply (18 to
32 VAC) is marked "ER". The high voltage (120
to 277 VAC) power supply is marked "ST".
6
UV Lamp Connection
1. When all the other components are properly installed connect the UV Lamp
cable to the Power supply cable.
2. Make sure the anges are aligned and then push the connectors rmly
together. A tight connection ensures a proper water-resistant seal.
Line-voltage "ST" wiring
2.
2.
1.
1.
7
Sight Glass Installation
1. Find a suitable location on the outside
of the duct-work near the UV Lamp
installation and apply the Fresh-Aire UV®
warning/lamp replacement sticker.
2. Drill a ½” hole through the orange circle
on the sticker. Press the UV safety viewport
into hole.
3. Turn on the power and use the sight glass
to conrm that the UV Lamp is operating.
"ER" 18 - 32 VAC Power Supply
"ST" 110 - 277 VAC Power Supply
24 VAC
IMPORTANT! Must be wired to constant power - do not connect to blower relay.
IMPORTANT!
Systems with high 24 VAC loads may require the installation of a separate 24 VAC
transformer to power the UV light.
Always use a separate 24 VAC transformer with communicating” air systems.
Draws 16 VA, may need to do load calculation: Volts under load X Amps under load.
TUVL-115P & TUVL-115P-OS
Note: Use of replacement UV lamps other than Fresh-Aire UV® voids warranty.
Caution: UV lamps contain small amounts of mercury - dispose of lamps in accordance
with local environmental regulations. For more information visit www.lamprecycle.org
TUVL-215P & TUVL-215P-OS
AIR HANDLER
24 VAC
TRANSFORMER
24 VAC
POWER SUPPLY
UV LAMP
BLUE CABLE
BLACK
RED
Low-voltage "ER" wiring
24 VAC TRANSFORMER
COMMON / BLUE
HOT / RED
Manufacturers Warranty:
This warranty supersedes and replaces any warranty statements orally made by the Sales Person, Distributor or Dealer or contained in the written instructions or other
Brochures or informational documents in relation to this product. This warranty gives you specic legal rights, and you may also have other rights which vary from
State to State.
What Does This Warranty Cover? This lifetime limited manufacturer warranty covers any defects or malfunctions in material and workmanship under the normal use
and service when operated and maintained in strict accordance with manufacturer’s instructions for the Lifetime of the equipment.
How Long Does The Coverage Last? 1) Power Supply: For as long as you own the real property where the product is installed. 2) TUVL-1XX Series Ultraviolet Lamp
is warranted for germicidal output for one-year from the date of installation. 3) TUVL-2XX Series Ultraviolet Lamp is warranted for germicidal output for two (2) years
from the date of installation. This warranty is not transferable.
What Will Triatomic Environmental, Inc. Do? Triatomic Environmental, Inc. will replace any defective or malfunctioning part at no charge. You must pay any labor
charges and shipping charges of defective product to our warranty department.
What Does This Warranty Not Cover? THIS PRODUCT IS NOT INTENDED TO BE PURCHASED AND INSTALLED BY UNLICENSED HVAC OR ELECTRICAL CONTRACTORS. This
warranty does not cover products or parts purchased from any source other than licensed HVAC or electrical contractors. This warranty does not cover parts installed
by unlicensed HVAC or electrical contractors. This warranty does not cover parts damaged as a result of misuse, abuse, or any use other than its intended use, accident,
acts of god, neglect, or from improper operation, maintenance, installation, modication or adjustments. Triatomic Environmental, Inc. shall have no responsibility for
charges incurred by the customer for installation or removal of warranted items.
This warranty does not cover parts or equipment used with the Fresh-Aire UV system that are not manufactured by Triatomic Environmental, Inc.
**This warranty shall be void if UV lamps from manufacturer’s other than Triatomic Environmental, Inc. are used with this equipment.
Consequential and incidental damages are not recoverable under this warranty. Manufacturer assumes no liability for any harm, which may occur as a result of the
use of the equipment herein and shall not be liable for consequential or any other damages whether or not caused by manufacturer’s negligence or resulting from any
express or implied warranty or breach thereof. Consequential damages for the purpose of this warranty shall include, but not be limited to, loss of use, income or
prot, or loss of or damages to property or injury or death to persons or animals occasioned by or arising out of operation, use, the operation, installation, repair or
replacement of the equipment or otherwise. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
There are no Warranties which extend beyond the description of the face hereof.
How Do You Get Service? In order to be eligible for service under this warranty you MUST return the warranty registration card or register online at www.freshaireuv.
com. If something is wrong with your product, call your installing contractor to receive a Return Merchandise Authorization (RMA) and instructions for returning the
product to a licensed distributor in your area or the manufacturer.
Once the product is returned, we will inspect your product and contact you within 10 business days of our receipt of the product to give the results of our inspection. If
we determine that the product is covered under this warranty, we will ship to you at no additional cost a replacement part. Replacement parts may be refurbished. If we
determine that the product is not covered under this warranty, or that this warranty is void, the product will be returned to you COD. There is no charge for inspection.
How Does State Law Apply? This warranty gives you specic legal rights, and you may also have other rights which vary from state to state.