APCO Owners Manual

F
WARNING
WARNING
In-Duct Air Purif ier
APCO® reduces odors (volatile organic compounds) and
biological contaminants such as mold, bacteria,
viruses, and allergens in indoor air. The
system is installed in the duct work of
the central air system. The award-
winning design of APCO® uses a
unique combination UVC light and
activated carbon cells to clean the air.
IMPORTANT!
Only qualified technicians should install this product*
Install in accordance with relevant building codes
Read instructions carefully including safety warnings
WARNING!
PROTECT EYES FROM UV LIGHT
TURN OFF UNIT OR DISCONNECT
BEFORE SERVICING
© Fresh-Aire UV TUV-APCO-MAN 4.18.19
*Installation of this product by anyone other than licensed HVAC or electrical contractors voids warranty.
US patent #7,704,463
Parts List
A
APCO® Main Unit
B
UV Lamp 1 Year*
C
UV Lamp 2 Year*
D
Duct Plate
E
Gasket
F
Power Cord (ER Model)
G
Self-tapping Screws
H
Quick Nut (plastic)
I
Machine Screws (on cover)
J
Tap-in Connector
K
Spade Connector
L
Optional Remote
UV Lamp 1 Year
M
Optional Remote
UV Lamp 2 Year
N
Sight Glass
O
“Z” Mounting Bracket
P
Warning Sticker
Note: lamp
L
or
M
and parts
N O P
are included with APCO Dual.
*Note: only one lamp is included with APCO.
B
C
D E
A
IHG J K
P
N
O
L
M
Air Handler
1
Installation Notes
APCO is usually installed on the supply side duct just
above the air system (upstream of a humidier if
there is one). but can also be installed on the return
side if necessary.
The APCO unit should be oriented so that
the air ows past the UV Light rst then into
the Matrix Element. Position the APCO unit
so the UV light does not shine directly
on non-uv-resistant materials (lters,
humidiers, ex duct, etc.). If possible
orient APCO so UV light shines on the
cooling coils.
If a second optional UV lamp is used
(APCO Dual) select a location inside the
air system that will allow it to shine on the
greatest surface area or the area with the
most evident microbial growth. To install
the secondary UV light use the Optional
2nd Remote UV Light Installation
Instructions provided with APCO Dual.
Typical installations include:
A
Furnace installation
B
Air handler installation
Optional
2nd UV Lamp
Filter media
B
Furnace
A
Optional
2nd UV
Lamp
Humidier
1. Use gasket to trace cut-line onto duct.
2. Cut hole in sheet metal or duct board.
IMPORTANT! Remove and dispose of
cut-out piece of material.
3. For sheet metal duct secure mounting plate to
sheet metal ducts using self-tapping screws.*
4. Remove paper backing from one side of gasket
and x gasket to the back of the mounting plate.
5. Remove paper backing from back of gasket then
x mounting plate and gasket to the duct.
6. Bend mounting plate anges around the edges of
the hole to secure mounting plate. For duct board
use tape on edges of mounting plate for air leaks
and additional hold.
* To install APCO without backing plate mount with
(4) self-tapping screws.
2
Duct Mounting
1.
4.
2.
5.
2. 3. 4.
3
Attach Power Unit to Duct & Mount UV Lamp
1. Fit the APCO® Main Unit through hole in duct.
If attaching directly to metal duct use (4) Self-
tapping Screws. If the Backing Plate is used t the
unit over the threaded posts and use (4) Quick
Nuts to secure it.
2. Insert UV Lamp.
3. Mount UV Lamp using (2) Quick Nuts and
attach lamp connector (be sure to align the four
connector pins).
4. Attach the cover with machine screws.
B C
or
I
I
J
1.
4
Connecting to Power
IMPORTANT
Before connecting to power conrm which APCO model is being installed. Turn o main
power source before installation. Always use proper conduit ttings and terminations.
Model information is printed on the Power Unit cover.
IMPORTANT! Must be wired to constant power - do not connect to blower relay.
Connect to load side of HVAC
Connect to load side of 24 VAC transformer
APCO
ER/DER
APCO
SI/DI
120-277 VAC
POWER SUPPLY
UV LAMP
4 PIN
CONNECTOR
L1 - BLACK
L2 or N - WHITE
GND - GREEN
Optional 2nd UV Lamp
24 VAC
POWER SUPPLY
UV LAMP
BLACKBLACK
4 PIN
CONNECTOR
REDWHITE STRIPE
24 VAC TRANSFORMER
COMMON / BLUE
HOT / RED
Connector
Optional 2nd UV Lamp
Manufacturers Warranty:
This warranty supersedes and replaces any warranty statements orally made by the Sales Person, Distributor or Dealer or contained in the written instructions or other
Brochures or informational documents in relation to this product. This warranty gives you specic legal rights, and you may also have other rights which vary from
State to State.
What Does This Warranty Cover? This lifetime limited manufacturer warranty covers any defects or malfunctions in material and workmanship under the normal use
and service when operated and maintained in strict accordance with manufacturer’s instructions for the Lifetime of the equipment.
How Long Does The Coverage Last? 1) Power Supply: For as long as you own the real property where the product is installed. 2) TUVL-1XX Series Ultraviolet Lamp
is warranted for germicidal output for one-year from the date of installation. 3) TUVL-2XX Series Ultraviolet Lamp is warranted for germicidal output for two (2) years
from the date of installation. This warranty is not transferable.
What Will Triatomic Environmental, Inc. Do? Triatomic Environmental, Inc. will replace any defective or malfunctioning part at no charge. You must pay any labor
charges and shipping charges of defective product to our warranty department.
What Does This Warranty Not Cover? THIS PRODUCT IS NOT INTENDED TO BE PURCHASED AND INSTALLED BY UNLICENSED HVAC OR ELECTRICAL CONTRACTORS. This
warranty does not cover products or parts purchased from any source other than licensed HVAC or electrical contractors. This warranty does not cover parts installed
by unlicensed HVAC or electrical contractors. This warranty does not cover parts damaged as a result of misuse, abuse, or any use other than its intended use, accident,
acts of god, neglect, or from improper operation, maintenance, installation, modication or adjustments. Triatomic Environmental, Inc. shall have no responsibility for
charges incurred by the customer for installation or removal of warranted items.
This warranty does not cover parts or equipment used with the Fresh-Aire UV system that are not manufactured by Triatomic Environmental, Inc.
**This warranty shall be void if UV lamps from manufacturer’s other than Triatomic Environmental, Inc. are used with this equipment.
Consequential and incidental damages are not recoverable under this warranty. Manufacturer assumes no liability for any harm, which may occur as a result of the
use of the equipment herein and shall not be liable for consequential or any other damages whether or not caused by manufacturer’s negligence or resulting from any
express or implied warranty or breach thereof. Consequential damages for the purpose of this warranty shall include, but not be limited to, loss of use, income or
prot, or loss of or damages to property or injury or death to persons or animals occasioned by or arising out of operation, use, the operation, installation, repair or
replacement of the equipment or otherwise. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
There are no Warranties which extend beyond the description of the face hereof.
How Do You Get Service? In order to be eligible for service under this warranty you MUST return the warranty registration card or register online at www.freshaireuv.
com. If something is wrong with your product, call your installing contractor to receive a Return Merchandise Authorization (RMA) and instructions for returning the
product to a licensed distributor in your area or the manufacturer.
Once the product is returned, we will inspect your product and contact you within 10 business days of our receipt of the product to give the results of our inspection. If
we determine that the product is covered under this warranty, we will ship to you at no additional cost a replacement part. Replacement parts may be refurbished. If we
determine that the product is not covered under this warranty, or that this warranty is void, the product will be returned to you COD. There is no charge for inspection.
How Does State Law Apply? This warranty gives you specic legal rights, and you may also have other rights which vary from state to state.
5
Lamp Replacement
The germicidal UV lamp in APCO needs
to be replaced periodically. TUVL115
lamps should be replaced every year.
TUVL215 should be replaced every 2
years. Note: UV lamps will continue to
emit visible light but lose germicidal
eectiveness over time. You can upgrade
to a 2 year lamp with your existing APCO
Power Unit.
CAUTION!
UV lamps contain small amounts of mercury - dispose of lamps in accordance with
local environmental regulations. For more information visit www.lamprecycle.org
Note: Use of replacement UV lamps other than Fresh-Aire UV® voids warranty.
TUVL215 (2 Year)
D
E
TUVL115 (1 Year)
IMPORTANT!
Systems with high 24 VAC loads may require the installation of a separate 24 VAC
transformer to power the UV light.
Always use a separate 24 VAC transformer with communicating air systems and all
APCO Dual (TUV-APCO-DER) models.
Draws 16 VA, may need to do load calculation: Volts under load X Amps under load.
6a. 6b.
3.
APCO in return duct with
light shining away from
lter media

Summary of content (2 pages)