Brochure

6 | CHILL
®
PREMIER SMART ROOM AIR CONDITIONERS
Model UPC
Cooling
Btu
Heating
Btu
Volts
Rated
Cooling
Amps
Cooling
Watts EER CEER
Estimated
Yearly
Energy Cost
Moisture
Removal-
Pints/HR Refrigerant CFM
Wt.
Net/Ship
Lbs.
SLIDE OUT CHASSIS, COOL ONLY
CCW06B10B 724587440249 6000 115 4.3 492 12.1 12.1 $54 0.9 R32 200 44/51
CCW08B10B 724587440256 8000 115 5.8 661 12.0 12.0 $69 1.0 R32 250 44/61
CCW10B10A 724587439472 10000 115 7.3 826 12.1 12.0 $95 1.2 R410A 300 51/68
CCW12B10A 724587439489 12000 115 8.6 992 12.0 12.0 $107 1.5 R410A 330 64/86
CCW15B10A 724587439496 15000 115 11.0 1270 11.8 11.8 $125 2.0 R410A 400 73/93
CCW18B30A 724587439502 18000 230 7.1 1525 11.8 11.8 $149 2.7 R410A 520 106/136
CCW24B30A 724587439519 24000 230 10.2 2308 10.3 10.3 $227 2.7 R410A 590 117/144
SLIDE OUT CHASSIS, HEAT & COOL
CEW08B11A 724587439526 8000 4200 115 6.3 670 11.0 11.0 $61 2.1 R410A 250 44/61
CEW12B33A 724587439533 12000 10600 230 4.8 1060 11.0 10.9 $96 3.3 R410A 265 64/86
CEW18B33A 724587439540 18000 10600 230 7.2 1600 11.0 11.0 $159 5.5 R410A 430 106/136
CEW24B33A 724587439557 24000 10600 230 10.6 2340 10.1 10.1 $222 6.5 R410A 560 117/144
INSTALLATION
* Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.
ENERGY STAR
®
models
CIRCUIT RATING/ BREAKER/POWER CORD
Model
Circuit Rating
Breaker or
T-D Fuse
Plug Face
(NEMA#)
Power Cord
Length (ft.)
Wall Outlet
Appearance
CCW06B10B, CCW08B10B, CCW10B10A,
CCW12B10A, CEW08B11A
125V 15A 5 15P
6
CCW15B10A 5.5
CCW18B30A, CCW24B30A
250V - 20A 6-20P
4
CEW12B33A, CEW18B33A, CEW24B33A 6
HEAT AND COOL MODELS
Chill Premier Electric Heat models utilize an
electric heat strip to provide warm air quickly.
They can be used for primary heating in mod-
erate climates and as supplemental heating in
colder climates. They are ideal for rooms that
are always ‘too cold in winter’.
Your Friedrich dealer or distributor can
assist you in selecting the right Chill Premier
unit for your particular climate and application.
COOL & HEAT
WINDOW OR THRU-THE-WALL INSTALLATION MODELS
SPECIFICATIONS
Power cord is located on front left side of Chill Premier units.
WINDOW INSTALL ATION THRU-WALL INSTALLATION
Model
Height
Inches
Width
Inches
Depth
Inches
Depth
From
Front to
Louvers
Window Width
Inches
Thru-the-wall
Finished Hole Inches
Carton Dimensions
Inches
Minimum* Maximum Height Width Height Width Depth
CCW06B10B, CCW08B10B 13
1
/
2
18
5
/
8
19
3
/
4
6 23 36 14 19
1
/
4
15 21
1
/
2
22
CEW08B11A, CCW10B10A,
CCW12B10A, CEW12B33A,
15
1
/
8
19
3
/
4
24
1
/
8
9
1
/
2
26 36 16 20
1
/
4
17 22 26
CCW15B10A, CCW18B30A,
CEW18B33A
18
23
7
/
8
25
3
/
8
8
1
/
5
28 41 19 24 19
3
/
8
25
5
/
8
29
5
/
8
CCW24B30A, CEW24B33A
18
5
/
8
26
1
/
2
27 10
3
/
5
30 41 20 27
1
/
4
19
1
/
2
29
1
/
4
31
LISTED
ROOM AIR CONDITIONERS
183H
As an ENERGY STAR
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR
®
models meet the
ENERGY STAR
®
guidelines for energy efciency.
EER is the unit’s Energy Efciency Ratio; CEER is the unit’s Combined Energy Efciency Ratio.
Your energy costs will depend on your utility rates and use. The estimated energy cost is based on an electricity cost of $.12 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.