Service and Parts Manual (2021, 2022)

15 PB
OPERATION
Sequence of Operation
 









35.6°
F
39.2°F
Auto fan speed in cooling mode
2. Dry mode
While selected to Dry mode, AC works at set temperature to 44.6°F for 3 minutes. After that the set temperature change to be
RT 28.4°F, the compressor works as cooling mode, and indoor fan motor operates at low speed.
The fan speed can not be changed while in dry mode, but the air direction can be adjusted.
3. I FEEL Mode
3.1 The operation mode and initial ST are generated by the Initial RT, and the operation mode is enabled once unless AC
is switched off and powered on again. While I FEEL is changed from other mode , the AC will operate based on the RT
temperature judgement.
3.2 PCB with Auto Restart Function, while power on again,
a). With Auto Restart Function activated, AC runs according to the temperature judgement.
b). If without Auto Restart Function or the function is shut off, AC works on stand by.
Operation MODE Initial RT Initial ST
Cooling
RT ≥78.8ºF 73.4ºF
Dry
RT
RT-
RT
Heating for Heat Pump or
Fan for Cooling Only.
78.8ºF
73.4ºF
35.6°F
28.4°F
35.6°F
When AC works in Dry mode after judgement, the display temperature ranges from 3.2°F to 87.8°F, and the set temperature ranges from 41°F to
87.8°F.
When AC works in Fan mode, the set temperature is fixed to 73.4°F, and displays room temperature.
In I FEEL mode (I FEEL cooling or heating), and the PCB receives instructions of temperature adjustment as increasing or decreasing from remote
control, the unit sets ST as the current room temperature±1°F.
( in heating mode, the RT need to be compensated), I FEEL temperature adjusts : ±3.6°F and buzzer responds but the controller
takes no action. The set temperature range is from: 60.8°F -87.8°F.
Only works on Cooling or Heating of I FEEL mode, the unit has above temperature control process. In I FEEL Dry or Fan mode, the
buzzer responds, but does not have control of any other operation.