Service and Parts Manual (2019, 2020, 2021, 2022)
Table Of Contents
- INTRODUCTION
- SPECIFICATIONS
- INSTALLATION
- MAINTENANCE
- R-410A SEALED SYSTEM REPAIR
- TROUBLESHOOTING
- Diagnostic Codes
- Outdoor Unit
- Outdoor Unit When The Compressor Is In Operation
- Indoor Unit
- Led Display
- Test the jumper terminals
- Protection Circuit Fault Isolation
- Compressor Fault Isolation
- Electric FIlter Board Fault Isolation
- Electrical Communication Fault ISOLATION
- Unit does not run
- Error Code 39-DC FAN
- Error Code 39-PG Fan
- Error Code 9
- Error Code 13
- Error Code 8
- Error Code 15
- Error Code 16 Cooling Mode
- Error Code 16 Heating Mode
- Error Code 21 Cooling Mode
- Error Code 11 EEPROM Fault
- Error Code 20
- Error Code 33
- Error Code 34
- Error Code 14
- Error Code 1
- Error Code 2
- Error Code 6
- COMPONENTS TESTING
- WIRING DIAGRAMS
- PARTS CATALOG
- Introduction
- 115V Indoor Unit 9-12K
- 230V Indoor Unit 9-12K
- 230V Indoor Unit High Seer 9K
- 230V Indoor Unit High Seer12K
- 230V Indoor Unit 18K
- 230V Indoor Unit 24K
- 230V Indoor Unit 36k
- 115V Outdoor Unit 9K
- 115V Outdoor Unit 12K
- 230V Outdoor Unit 9k
- 230V Outdoor Unit 12k
- 230V Outdoor Unit 18k
- 230V Outdoor Unit 18k
- 230V Outdoor Unit 24k
- Outdoor Unit 36k
- 230v Outdoor Unit 9K HIGH SEER
- 230V Outdoor Unit 12K HIGH SEER
- APPENDIX
- LIMITED WARRANTY
- CUSTOMER SATISFACTION and QUALITY ASSURANCE
- FRIEDRICH AUTHORIZED PARTS DEPOTS
20 PB
OPERATION
Sleep mode will cease after 8 hours of operation.
Using Sleep during Off-Timer Function
When using Sleep mode, if the next OFF-Timer setting less than 8 hours, Sleep mode will remain active until the OFF-Timer
setting. If the next OFF-Timer setting more than 8 hours, it will override the OFF-Timer setting and will turn the system off 8
hours after engaging Sleep mode.
Auto Mode (SMART)
In Auto Mode (SMART) the system will automatically switch to Cooling, Heating, Dry or Fan Only modes based on the current
room temperature. Air ow direction can be adjusted in any mode.
The auto set point is determined by the user.
When the room temperature is 79°F or above, Cooling mode will activate.
When the room temperature is between 73°F and 79°F, Dry mode will activate. Fan Speed will drop to LOW after 3 minutes.
When the room temperature is between 70°F and 73°F, Fan only mode will activate. Fan Speed is automatically set to LOW,
but can be adjusted when between these room temperatures.
When the room temperature is below 70°F, Heating mode will activate. The room temperature is set to 72°F.
Auto Mode ceases when another specic operation mode is selected. If changing between Cooling and Heating modes, the
compressor ceased for operation for 5 minutes.
Cooling only appliance
a. When the room temperature exceeds 79°F, it will be ran in Cool mode, and the temperature is set to 79°F.
b. When the room temperature exceeds 73°F, but not more than 79°F, it will be operated in the Dry mode.
c. When the room temperature is not more than 73°F, it will be operated in the Fan only, the air volume is set to LOW and the
fan speed can be adjusted
Cooling Mode
Outdoor Fan
The outdoor fan’s speeds (except in single speed-selection motors) is changed automatically according to outdoor ambient
temperatures demands. When operating at a xed frequency, the outdoor fan is forced to operate at the highest speed.
Indoor Fan
While in Cooling or Heating modes, the indoor fan speed is controlled by the remote control: High, Medium, Low and
Automatic setting. When in Automatic speed in the Cool mode for the rst time, the fan speed will run at Low setting. After
that, temperature and fan speed selection are in Automatic is shown in Fig.302
When the temperature difference is lower than 5F, Low fan speed will engage. When the difference between the setpoint
temperature and the room temperature is between 5F to 10F, the indoor fan speed will keep in Medium Speed. When the
temperature difference is above 10F, High fan speed will engage.
7.2ºF
3.6°F
Figure 302