Service and Parts Manual (2019, 2020, 2021, 2022)
Table Of Contents
- INTRODUCTION
- SPECIFICATIONS
- INSTALLATION
- MAINTENANCE
- R-410A SEALED SYSTEM REPAIR
- TROUBLESHOOTING
- Diagnostic Codes
- Outdoor Unit
- Outdoor Unit When The Compressor Is In Operation
- Indoor Unit
- Led Display
- Test the jumper terminals
- Protection Circuit Fault Isolation
- Compressor Fault Isolation
- Electric FIlter Board Fault Isolation
- Electrical Communication Fault ISOLATION
- Unit does not run
- Error Code 39-DC FAN
- Error Code 39-PG Fan
- Error Code 9
- Error Code 13
- Error Code 8
- Error Code 15
- Error Code 16 Cooling Mode
- Error Code 16 Heating Mode
- Error Code 21 Cooling Mode
- Error Code 11 EEPROM Fault
- Error Code 20
- Error Code 33
- Error Code 34
- Error Code 14
- Error Code 1
- Error Code 2
- Error Code 6
- COMPONENTS TESTING
- WIRING DIAGRAMS
- PARTS CATALOG
- Introduction
- 115V Indoor Unit 9-12K
- 230V Indoor Unit 9-12K
- 230V Indoor Unit High Seer 9K
- 230V Indoor Unit High Seer12K
- 230V Indoor Unit 18K
- 230V Indoor Unit 24K
- 230V Indoor Unit 36k
- 115V Outdoor Unit 9K
- 115V Outdoor Unit 12K
- 230V Outdoor Unit 9k
- 230V Outdoor Unit 12k
- 230V Outdoor Unit 18k
- 230V Outdoor Unit 18k
- 230V Outdoor Unit 24k
- Outdoor Unit 36k
- 230v Outdoor Unit 9K HIGH SEER
- 230V Outdoor Unit 12K HIGH SEER
- APPENDIX
- LIMITED WARRANTY
- CUSTOMER SATISFACTION and QUALITY ASSURANCE
- FRIEDRICH AUTHORIZED PARTS DEPOTS
21 PB
OPERATION
Air ow direction (Louvers) control
The louver is operated by a stepper motor and operates the horizontal swing of the louver automatically. Press the SWING
button to start or stop the louver swing.
During the louver swing in normal operation, the current position will be stored. When the appliance turns off and the louvers
swing automatically to the default position, it will position at the close position plus 5º.
4-way valve
State: It is interrupted in cooling.
Switchover: When initially powered on for cooling, the 4-way valve is interrupted immediately.
When the heating is changed to the cooling, it needs an interval of 50 seconds for the 4-way valve to change over from being
activated to being interrupted.
Heating-run mode
Temperature compensation
The temperature compensation is 5º in heating mode. For example, if the set temperature is 77ºF(25°C) by the remote
control, when the room temperature is detected with 88ºF(31°C), the compressor will turn off. The main reason is that the hot
air is condensed at the top of the house.
Note: The compensation is available only if the room temperature sensor of indoor unit is used and it is not available when it
is subject to the sensor on the remote control.
Indoor fan motor operation
Anti-cold air system:
When the appliance run in Heat mode condition, the indoor fan motor operation is shown in Figure 303 to prevent the cooling
air come out during the appliance operation.
95ºF
86°F
77°F
When the difference between the setting temperature and the room temperature equal to 2º or 4º, the indoor fan speed will
keep in current speed.
Air ow direction control
The horizontal louver is controlled by a step motor, press the SWING button to swing or stop the louver.
During the louver run in normal operation, the current position will be stored. When the appliance turn off and louver swing
automatically to the default position, it will position at the default position plus 5º.
Outdoor fan
The outdoor fan speeds except single speed motor can be changed according to outdoor ambient temperatures.
4-way valve
State: It is electried in heating.
Switchover: When initially powered on for heating, the 4-way valve is activated immediately.
In the change from cooling to heating, it needs an interval of 50 seconds for the 4-way valve to change over from being
interrupted to being activated.
The super function (option)
In cooling mode, when you press the SUPER button by remote control, the unit will operate for 15 minutes with the following
setting:
a. The set temperature is 16º(61°F);
b. The fan speed with highest speed;
c. The compressor runs with high frequency.
Figure 303