Friedrich Chill Air Conditioners Brochure

Thru-the-wall Specifications
ENERGY STAR
®
models
WALLMASTER HEAT PUMP
HEATING PERFORMANCE: Change-over from heat pump operation to resistance
operation on models indicated is automatic at a preset outside ambient temperature
of approximately 35°F.
Calculate the heat loss of the space to be heated. As long as the heat loss does
not exceed the resistance heating capacity rating of the unit, the heating perfor-
mance will be satisfactory.
Note: all models will produce condensate. If condensate disposal is desired, an
optional drain kit is available.
DEFROST CONTROL: Initiated at 30°F (outdoor coil temperature) and terminated
at 43°F (outdoor coil temperature). During defrost, the compressor stops and the
electric heat starts, then operates with the fan to maintain indoor comfort. Below
43°F, the unit remains in electric heat mode.
DEFROST DRAIN: Drain automatically opens at approximately 50°F to prevent
condensate from freezing inside drain pan.
WallMaster Heat Pump heating information (shown in red) indicates heat pump heating performance. WallMaster Electric Heat heating information (shown in red)
indicates electric heat strip performance. For WallMaster Heat Pump electric heating performance refer to corresponding WallMaster Electric Heat model.
LISTED
ROOM AIR CONDITIONERS
183H
Thru-the-wall Optional Accessories
Model Height Width Depth
Depth
with
Front
Minimum
Extension
Into Room
Minimum
Ex tension
Outside
Thru-the-wall
Finished Hole
Height Width Max. Depth
WallMaster
®
WSE Sleeve 16 3/4" 27" 16 3/4" 23" 7 1/2" 9/16" 17 1/4" 27 1/4" 15 5/16"
Chassis 15 3/4" 26 1/2" 21" 22”
Uni-Fit
®
USC Sleeve 15 1/2" 25 7/8" 16 3/4" 20 1/2" 1/2" 15 3/4" 26 1/8" 16 1/4"
US Chassis 14 3/8" 24" 18 1/2 20 1/8" 3 3/4"
UE Chassis 14 3/8" 24 5/8" 18 19 5/8" 3 1/2"
Sleeve/Chassis Dimensions
IMPORTANT:
US chassis w/front fully installed into USC sleeve
extends into room 3
3
/8”. UE chassis w/front fully
installed into USC sleeve extends into room 2
7
/8”. 1” gap on sides and
1
/2” gap at top can be
covered by two-piece trim ring that ts over the
chassis front
STANDARD GRILLE – Ships with USC sleeve
Expanded aluminum grille designed for use with USC sleeve.
REPLACEMENT GRILLE – Ships with US/UE chassis
Black plastic for use on existing sleeves without any grille.
IMPORTANT:
When installing into an existing sleeve, consult Installation
Section of your Installation/Operation Manual to determine
whether or not the grille needs to be replaced and/or a bafe
adapter should be used.
Uni-Fit
®
26” Sleeve Exterior Grilles
USC Sleeve Standard Grille
Installation Accessories (27” sleeve models only)
IMPORTANT:
Operating the air conditioner
with incorrect rear grille or
without Bafe Adapter Kit
(on 19 3/4” deep sleeve) will
recirculate discharge air and
cause compressor overload
to trip.
This will cause the unit to shut
down temporarily and may
lead to premature compressor
failure.
CORRECT Vertical Louvers
INCORRECT Horizontal Louvers
WallMaster
®
27” Sleeve Exterior Grilles
WSE SLEEVE
Optional Architectural Grille- AG
Premium brushed aluminum
grille.
WSE SLEEVE
Standard Grille
Premium, stamped steel grille
with powder coat paint. Ships
with sleeve. Galvanized steel
inner and outer weather panels
also ship with sleeve.
DK / Drain Kit
Installed at the back of the unit and allows for
attachment to condensate disposal system, if
necessary or desired.
IDK / Internal Drain Kit
New construction applications
where a condensate drain system
has been built into the wall interior.
BAK / Bafe Adapter Kit
Necessary when installing in
a sleeve deeper than 16 3/4"
deep, such as Fedders B sleeve
(19 3/4" deep).
Trim ring
US= 3
3
/8”, UE= 2
7
/8
Model
Carton Dimensions
INCHES
Height W i d t h Depth
WallMaster
®
WSE Sleeve 18" 27 1/4" 18"
Chassis 15 3/4" 26 1/2" 21"
Uni-Fit
®
USC Sleeve 17 7/8" 28" 19 1/4"
US Chassis 17 1/4" 27" 22 1/4”
UE Chassis 17" 27 1/4" 22”
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
As an ENERGY STAR
®
partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR
®
models meet the ENERGY STAR
®
guidelines for energy efciency.
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity
cost of $ .12 per kWh. For more information, visit www.ftc.gov/energy.
Power cords are located on front left of WallMaster models and on front right of Uni-Fit models.
Optional Architectural Grille UXAA
Estar
Model Cooling Btu Heating Btu
Volts
Rated
Cooling
Amps
Cooling
Watts
Heating
Amps
Heating
Watts
Energy
Efciency
Ratio
EER
Estimated
Yearly
Energy
Cost COP
Moisture
Removal
Pints/HR CFM Sleeve
Net
Weight
Lbs.
Ship
Weight
Lbs
WALLMASTER
®
Cool only
WS08C10D 8000 - 115 6.4 769 - - 10.4
$69
- 1.2 250 WSE 93 97
WS10C10D 9700 - 115 8.2 990 - - 9.8 $89 - 2.4 260 WSE 103 107
WS12C10D 11500 - 115 11.5 1174 - - 9.8 $106 - 3.1 295 WSE 112 116
WS10C30D 10000/9800 - 230/208 4.5/4.9 1020/1000 - - 9.8/9.8 $92 - 1.5 260 WSE 101 105
WS12C30D 11500/11200 - 230/208 5.5/6.0 1174/1143 - - 9.8/9.8 $106 - 3.0 290 WSE 109 113
WS16C30 15600/15000 - 230/208 8.3/8.9 1835/1765 - - 8.5/8.5 $165 - 4.2 290 WSE 119 123
Heat Pump
WY09C33D 9300/9000 7500/7500 230/208 4.3/4.6 949/918 3.9/4.1 833/833 9.8/9.8 $85 2.6/2.6 2.1 260 WSE 103 107
WY12C33 12000/11800 9350/9200 230/208 6.1/6.4 1395/1372 4.8/5.1 1062/1010 8.6/8.6 $126 2.5/2.6 2.6 275 WSE 111 115
Cool with Electric Heat
WE10C33D 10000/9800 11000/9100 230/208 4.5/4.9 1020/1000 16.0/14.7 3550/2950 9.8/9.8 $92 - 1.5 260 WSE 104 108
WE12C33D 11500/11200 11000/9100 230/208 5.5/6.0 1174/1143 16.0/14.7 3550/2950 9.8/9.8 $106 - 3.0 290 WSE 107 111
WE16C33 15600/15000 11000/9100 230/208 8.3/8.9 1835/1765 16.0/14.7 3550/2950 8.5/8.5 $165 - 4.2 290 WSE 119 123
UNI-FIT
®
Cool Only
US08D10B 8000 - 115 7.4 810 - - 9.8 $73 - 2.2 260 USC 73 79
US10D10B 9800 - 115 9.2 1000 - - 9.8 $90 - 3.2 260 USC 78 84
US12D10B 11500 - 115 10.7 1170 - - 9.8 $106 - 3.8 TBD USC 80 87
US10D30B 10000/9800 - 230/208 4.7/5.1 1020/1000 - - 9.8/9.8 $92 - 3.2 285 USC 78 86
US12D30B 11500/11200 - 230/208 5.4/5.8 1170/1140 - - 9.8/9.8 $106 - 3.8 260 USC 80 87
US14D30B 13000/12600 - 230/208 7.0/7.5 1530/1480 - - 8.5/8.5 $138 - 4.0 310 USC 87 94
Cool with Electric Heat
UE08D11B 8000 3850 115 7.5 830 10.7 1230 9.6 $77 - 2.2 260 USC 73 79
UE10D33B 10000/9800 11200/9200 230/208 4.7/5.2 1060/1040 15.3/14.0 3500/2900 9.4/9.4 $96 - 3.2 285 USC 78 84
UE12D33B 11500/11200 11200/9200 230/208 5.6/6.0 1220/1190 15.3/14.0 3500/2900 9.4/9.4 $110 - 3.8 290 USC 80 87
Plug Face/ Circuit Rating
WallMaster
®
Model Number
Uni-Fit
®
Model Number
Circuit
Rating
Breaker
or T-D Fuse
Plug
Face
(NEMA#)
Power
Cord
Length
(ft.)
Wall
Outlet
Appearance
WS08C10D, WS10C10D,
WS12C10D
US08D10B, UE08D11B
US10D10B, US12D10B
125V - 15A 5 - 15P 6
WS10C30D, WS12C30D,
WS16C30
US10D30B, US12D30B,
US14D30B
250V - 15A 6 - 15P 4
WE10C33D, WE12C33D,
WE16C33, WY09C33D, WY12C33
UE10D33B, UE12D33B 250V - 20A 6 - 20P 4
24