PERFORMANCE RATINGS 115 volt models 230/208 volt models
SYSTEM MODEL NO.
MM09YJ MM12YJ MM18YJ MM24YJ MM36YJ
INDOOR MODEL
MWM09Y1J MWM12Y1J MWM18Y3J MWM24Y3J MWM36Y3J
OUTDOOR MODEL
MRM09Y1J MRM12Y1J MRM18Y3J MRM24Y3J MRM36Y3J
SPECIFICATIONS
CAPACITY COOLING (RATED) Btu
9000 11800 18000 22000 33600
CAPACITY COOLING MIN - MAX Btu
3500~11000 3300~12500 4500~21000 6400~24000 7404~35997
COOLING AMPS
9.00 15.00 7.85/7.10 11.50/10.50 17.0/17.0
HEATING AMPS
9.50 15.5 11.77/10.65 12.80/13.00 16.5/16.5
SENSIBLE HEAT RATIO
0.79 0.73 0.77 0.77 0.75
CAPACITY HEATING (RATED) @ 47°F Btu
9800 13000 19200 24200 34600
CAPACITY HEATING MIN - MAX Btu
2500~11000 3400~13500 4000~23000 4100~26600 14979~35997
CAPACITY HEATING (RATED) @ 17°F Btu
5400 8500 13500 18600 20200
HSPF
8.6 8.6 8.5 8.5 9.0
SEER
16.0 16.0 16.0 16.0 18.0
EER
12.0 9.4 11.0 10.0 8.20
MOISTURE REMOVAL Pts/h
1.69 2.96 3.80 4.50 7.40
AIRFLOW (HIGH/MED/LOW/QUIET) CFM
330/277/224/188 341/288/235/200 471/400/330/271 588/441/306/206 736/647/530/412
SOUND RATING - INDOOR (HIGH/MED/LOW/QUIET) dB-A
41/37/35/32 43/39/35/32 48/43/38/34 49/43/39/34 54/49/44/37
SOUND RATING - OUTDOOR dB-A
53 55 56 53 65
OPERATING RANGE (HEATING) °F
5-75 5-75 5-75 5-75 -4-75
OPERATING RANGE (COOLING) °F
32*-113 32*-113 5-118 5-115 0~109
EST. YEARLY OPERATING COST U.S. $
$67 $113 $146 $198 $368
ELECTRICAL DATA
POWER SOURCE V/Hz/Phase
115/60/1 115/60/1 208/230/60/1 208/230/60/1 208/230/60/1
MIN. AMPACITY A
13 15 15 16 24
COOLING WATTS W
750 1260 1620 2200 4100
HEATING WATTS W
830 1320 2400 2800 3800
MAX. TD FUSE/ BREAKER A
20 25 25 25 40
REFRIGERATION SYSTEM
REFRIGERANT
R410A R410A R410A R410A R410A
COMPRESSOR TYPE
Inverter Inverter Inverter Inverter Inverter
CONNECTIONS
Flare Flare Flare Flare Flare
LIQUID LINE O.D. in
1
/4
"
1
/4
"
1
/4
"
1
/4
"
1
/4
"
SUCTION LINE O.D. in
3
/8
"
3
/8
"
1
/2
"
1
/2
"
5
/8
"
REFRIGERANT CHARGE oz.
35.3 35.3 45.8 54.7 91.7
FACTORY PRECHARGE ft
24.6 24.6 24.6 24.6 24.6
MIN. / MAX. LINE LENGTH ft
7 / 65 7 / 65 10 / 82 10 / 82 98
MAX. HEIGHT DIFFERENCE ft
32 32 32 32 32
DIMENSIONS & WEIGHT
INDOOR UNIT
W x H x D in
30"× 11"× 8" 34"× 12"× 8" 39
11
/16
"× 12
3
/8
"× 8" 53"x 13"x 10"
NET WEIGHT lbs
19 19 26 33 42
SHIPPING WEIGHT lbs
25 25 35 44 52
OUTDOOR UNIT
W x H x D in
33
3
/8
"× 24
1
/4
"× 12
5
/8
" 37
5
/8
"x 27
5
/8
"x 15
5
/8
" 38
1
/4
"x 31"x 17"
NET WEIGHT lbs
68 68 106 115 161
SHIPPING WEIGHT lbs
77 77 117 126 172
TOTAL NET WEIGHT lbs
87 87 132 148 203
TOTAL SHIPPING WEIGHT lbs
102 102 152 170 224
SELECT SERIES SPECIFICATIONS
* Capacity is reduced as 32 degrees Fahrenheit is approached.
Due to continuing research in new energy-saving technology, specications are subject to change without notice.
All Friedrich ductless split products require a licensed contractor for installation.