Installation & Operation Manual
40 41
The following instructions apply to wood, masonry, brick, concrete or cinder
block wall construction.
STEP 1.  Follow Steps 1, 2, 3, and 4 of the “STANDARD WINDOW 
INSTALLATION” instructions beginning on Page 29.
STEP 2.  CABINET PREPARATION – Remove the sill plate from the 
cabinet by removing two (2) nuts and screws (Figure 78). 
Note that the chassis retainer is secured by a right side 
nut and screw (Detail A, Figure 78). Bend the tabs of the 
sill plate down into its channel at both ends of the plate or 
cut them off (Detail B, Figure 78). Rotate the sill plate 180° 
(end-to-end, Detail B, Figure 78) and reinstall. Reverse the 
orientation of the nuts and screws, so that the head of the 
screws are on the underside of cabinet facing up and the 
nuts are on top (Detail C, Figure 78). Ensure that the chassis 
retainer is reinstalled as shown in the detail.
STEP 3.  WALL PREPARATION – The maximum wall thickness permissible 
without special construction is determined by the model size to be 
installed. Observe the maximum wall thickness shown in Figure 79. 
Walls exceeding the maximum thickness shown in the chart should 
be altered as shown in Figure 79.
STEP 4.  CHECKING WIRING AND PLUMBING – Check for wiring 
and plumbing inside and outside of the wall to be sure none will 
be damaged when the cabinet framework is being constructed.
STEP 5.  OPENING CONSTRUCTION – Depending upon size of unit 
to be installed, lay out the hole dimensions per Table 3. Cut 
and  frame-in  the  opening  to  nished  dimensions.  If  the  wall 
construction is a typical frame, or 2″ x 4″ studding with brick or 
stone veneers, locate the opening next to one of the studs. For 
masonry, concrete, or cinder block walls, locate an opening for 
your convenience (see Figures 80, 81, and 82).
NOTICE
The outside cabinet condenser air intake louvers 
MUST NOT BE BLOCKED by extra thick walls.
Table 3
FINISHED
DIMENSION
SMALL
CHASSIS
MEDIUM
CHASSIS
LARGE
CHASSIS
A 16 
3
⁄16″ 18 
3
⁄16″ 20 
3
⁄8″
B 26 
3
⁄16″ 26 
3
⁄16″ 28 
1
⁄4″
NOTE: These dimensions are for nished opening size.
B
A
Thru-the-Wall Installation
WARNING
Falling Object Hazard
Not following Installation Instructions
for mounting your air conditioner can
result in property damage, injury, or
death.