SPECIFICATIONS
Electrical Data
WARNING
ELECTRIC SHOCK HAZARD 
Turn  off  electric  power  before  service  or 
installation.
All electrical connections and wiring MUST be 
the National Electrical Code and all local codes 
which have jurisdiction.
Failure to do so can result in personal injury or 
death.
NOTICE
FIRE HAZARD 
electically unsafe conditions which could cause moderate 
or serious property damage.
Read, understand and follow the above warning.
Circuit Rating/ Breaker/ power cord/ wall Receptacle
Model
Circuit Rating 
Breaker or
T-D Fuse
Plug Face 
(NEMA#)
Power Cord 
Length (ft.)
Required Wall 
Receptacle 
NEMA NO. 
Wall Outlet 
Appearance
KCQ06A10A, KCQ08A10A, 
KCQ10A10A, KCQ10A10B, 
KEQ08A11A
125V - 15A 5 - 15P 6
5-15R
Wire Size - Use ONLY wiring size recommended for single outlet branch circuit.
Fuse/ Circuit Breaker - Use ONLY the correct HACR type and size fuse/circuit breaker. Read electrical ratings on 
unit’s rating plate. Proper circuit protection is the responsibiity of the homeowner.
Grounding - Unit MUST be grounded from branch circuit through service cord to unit, or through separate ground 
wire provided on permanently connected units. Be sure that branch circuit or general purpose outlet is grounded.
Receptacle - The eld supplied outlet must match plug on service cord and be within reach of service cord. Do 
NOT alter the service cord or plug. Do NOT use an extension cord. Refer to the table above for proper receptacle 
and fuse type.
Figure 205 (Circuit Breaker / Plug / Receptacle / Cord Rating)