Service & Parts Manual (Non Q) (2019, 2020, 2021, 2022)
Table Of Contents
- INTRODUCTION
- SPECIFICATIONS
- OPERATION
- ROUTINE MAINTENANCE
- REMOVE AND INSTALL THE CHASSIS
- R-410A SEALED SYSTEM REPAIR
- COMPONENT TESTING- Hermetic Components Check
- Reversing Valve Description And Operation
- Testing The Reversing Valve Solenoid Coil
- Checking The Reversing Valve
- Replace The Reversing Valve
- Touch Test Chart : To Service Reversing Valves
- Compressor Checks
- Compressor Replacement
- Fan Motor
- Capacitors
- Heating Element
- Drain Pan Valve
- Testing the User Interface and Electronic Control Board
- Thermistors Description
- Electronic Control Board Identification
- Replace the Electronic Control Board
- Replace the User Interface
 
- TROUBLESHOOTING
- WIRING DIAGRAMS
- PARTS CATALOG
- Available Accessories
58 PB
COMPONENT TESTING 
Touch Test Chart : To Service Reversing Valves
DISCHARGE TUBE  
from Compressor  
Tube to INSIDE
  T
ube to INSIDE
Capillary Tube  
RIGHT Pilot
Capillary Tube  
Capillary Tube
LEFT Pilot
SUCTION 
to Compressor
TUBE to  
Compressor
Capillary Tube
COIL 
14
COIL
NORMAL FUNCTION OF VALVE 
VALVE 
OPERATING 
from Compressor
DISCHARGE TUBE
SUCTION TUBE
COIL
Tube to OUTSIDE
LEFT Pilot
RIGHT Pilot
CONDITION
NOTES:
1 2 3  4  6 5  POSSIBLE CAUSES 
* TEMPERATURE OF VALVE BODY
** WARMER THAN VALVE BODY
Hot 
Normal Cooling 
 CORRECTIONS 
 Cool 
Cool
as (2) 
Hot
as (1) 
*TVB   TVB 
Normal Heating 
Hot   Cool 
Hot
as (1) 
Cool
as (2) 
*TVB   TVB 
MALFUNCTION OF VALVE 
Valve will not 
to heat. 
shift from cool  
Check Electrical circuit and coil 
 Repair electrical circuit. No voltage to coil. 
 Replace coil. Defective coil. 
Check refrigeration charge 
 Repair leak, recharge system. Low charge. 
Pressure differential too high.   Recheck system. 
Hot   Cool 
 Cool, 
as (2) 
Hot,
as (1) 
 Hot *TVB  Pilot valve okay. Dirt in one bleeder hole. 
Piston cup leak 
Deenergize solenoid, raise head pressure, 
reenergize solenoid to break dirt loose.
If unsuccessful, remove valve, wash 
out. Check on air before installing. If no 
movement, replace valve, add strainer to
discharge tube, mount valve horizontally. 
Valve will not 
Stop unit. After pressures equalize, restart  
with solenoid energized. If valve shifts,
reattempt with compressor running. If still 
no shift, replace valve. 
shift from cool  
to heat. 
Hot   Cool 
Cool,
as (2) 
Hot,
 as (1) 
*TVB  *TVB   Clogged pilot tubes. 
Raise head pressure, operate solenoid to
free. If still no shift, replace valve. 
Hot   Cool 
Cool,
as (2) 
Hot,
 as (1) 
Hot   Hot 
Both ports of pilot open. (Back seat port 
did not close). 
 Cool Warm 
Raise head pressure, operate solenoid 
to free 
partially clogged port. If still no shift, 
replace
valve.
Cool,
as (2) 
Hot,
 as (1) 
*TVB   Warm   Defective Compressor.   Replace compressor 
Starts to shift 
complete
reversal.
but does not  
Hot   Warm   Warm   Hot   Hot  *TVB 
Check unit for correct operating pressures  
and charge. Raise head pressure. If no
shift, use valve with smaller port. 
Not enough pressure differential at start 
of stroke or not enough fl ow to maintain  
pressure differential. 
 Replace valve Body damage. 
Hot   Warm   Warm   Hot   Hot   Hot   Both ports of pilot open. 
Raise head pressure, operate solenoid. If 
no shift, use valve with smaller ports. 
 Replace valve  Body damage.  Hot *TVB Hot  Hot  Hot Hot 
Hot   Hot 
Raise head pressure, operate solenoid. If 
no shift, use valve with smaller ports. 
 Hot   Hot 
Valve hung up at mid-stroke. Pumping 
volume of compressor not suffi cient to 
maintain reversal. 
 Hot   Hot   Both ports of pilot open. 
Apparent
Raise head pressure, operate solenoid. 
If no
shift, replace valve. 
leap in heat-
ing.
Hot   Cool 
Hot,
as (1) 
Cool,
as (2) 
*TVB  *TVB   Piston needle on end of slide leaking. 
Hot   Cool 
Operate valve several times, then recheck.  
If excessive leak, replace valve. 
Hot,
as (1) 
Cool,
as (2) 
**WVB   **WVB   Pilot needle and piston needle leaking. 
Operate valve several times, then recheck.  
If excessive leak, replace valve. 
Will not shift 
cool.
from heat to  
Hot   Cool 
Hot,
as (1) 
Cool,
as (2) 
*TVB  *TVB   Pressure differential too high. 
Clogged pilot tube. 
Stop unit. Will reverse during equalization  
period. Recheck system 
Hot 
Raise head pressure, operate solenoid to
free dirt. If still no shift, replace valve. 
 Cool 
Hot,
as (1) 
Cool,
as (2) 
Hot  *TVB   Dirt in bleeder hole. 
Hot   Cool 
Hot,
as (1) 
Cool,
as (2) 
Hot 
Raise head pressure, operate solenoid.
Remove valve and wash out. Check on air  
before reinstalling, if no movement, replace  
valve. Add strainer to discharge tube. 
Mount valve horizontally. 
 Piston cup leak. *TVB 
Hot   Cool 
Hot,
as (1) 
Stop unit. After pressures equalize, restart 
with solenoid deenergized. If valve shifts, 
reattempt with compressor running. If it
still will not reverse while running, replace 
the valve. 
Cool,
as (2) 
 Replace valve.  Defective pilot.  Hot Hot 
Warm   Cool 
Warm, 
as (1) 
Cool,
as (2) 
Warm   *TVB   Defective compressor.   Replace compressor 
Figure 704 (Touch Test Chart)