Installation and Operation Manual
38 39
Figure 71
FRR055
ELECTRICAL CONTROL 
PANEL SCREWS (3)
Remove the 3 screws as shown from the electrical control panel.  
Save to reinstall later.
Figure 70
FRR054
ELECTRICAL 
CONTROL 
PANEL
NOTE:
DECORATIVE FRONT
REMOVAL USE TOOL PROVIDED.
(SEE FIGURE 69 FOR LOCATION OF TOOL)
Figure 72
FRR056
1 INCH
90°
Figure 73
FRR057
ELECTRICAL CORD 
STRAIN RELIEF
Figure 74
FRR058
ENSURE THE ELECTRICAL CORD STRAIN RELIEF IS FLUSH 
WITH THE TOP OF ELECTRICAL CONTROL PANEL.
Cord Routing Change
WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the
same configuration as your air conditioner’s
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong oulet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
For convenience and optimum appearance, the direction that the power 
cord exits  the unit may be  changed from left  to right by following  the 
procedure below. Select the exit location on the left or right based on 
proximity to the power outlet.
STEP 16. Carefully pull out electrical control panel 1″, but not all the way.
STEP 17. Pull electrical cord strain relief downward until free and rotate 
90 degrees to the right.
STEP 18. Push electrical cord strain relief back upward into the electrical 
control panel.
Unplug unit.