2014 Ductless Cassette Multizone Heat Pump Submittal
Refrigeration line sets*
*Insulated line sets are available for all Friedrich split systems in 15 ft. and 35 ft. lengths. Each line set is equipped with are nuts on both ends. Both liquid and suction lines
are insulated. Line sets can be joined together with eld supplied double male connectors.
Each system requires one line set for each indoor unit installed. On multi-zone systems, line sets should be ordered based on individual indoor unit capacities not total system
capacity.
WIRED
CONTROLLER USED WITH
DWC1 All models.
Ductless_Wall-mounted_Single_Zone_Hi-SEER_Submittal_2014
SPECIFICATIONS
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh. For more
information, visit www.ftc.gov/energy. Due to continuing research in new energy-saving technology,
specications are subject to change without notice.
USED WITH
Length
Ft.
Liquid Suction Kit#
9000 and 12000
BTU indoor units
15’ 1/4” 3/8” T32150
35’ 1/4” 3/8” T32350
18000 BTU indoor units
15’ 1/4” 1/2” T42150
35’ 1/4” 1/2” T42350
24000,30000 and 36000
BTU indoor units
15’ 3/8” 5/8” T53150
35’ 3/8” 5/8” T53350
WIND
BAFFLE
USED WITH
DLAWB1 9000 - 12000 Btu wall-mounted
single zone models
DLAWB2 18000 - 36000 Btu wall-mounted
single zone models
Low ambient wind baffle kitThermostat
PERFORMANCE RATINGS Single Wall Mounted - H/P Inv (High SEER)
12k
SYSTEM MODEL NO. HM12YJ
INDOOR MODEL MWH12Y3J
OUTDOOR MODEL MRH12Y3J
SPECIFICATIONS
CAPACITY COOLING RATED Btu 12,000
CAPACITY COOLING MIN~MAX Btu 3070~14660
CAPACITY HEATING
@
47
0
F RATED Btu 13,600
CAPACITY HEATING MIN~MAX Btu 3070~20470
COOLING AMPS 3.8
HEATING AMPS 4.3
SENSIBLE HEAT RATIO .84
SEER 25.0
EER 14.0
HSPF 11.0
ENERGY STAR Yes (Most Ecient)
MOISTURE REMOVAL Pts/h 1.7
AIRFLOW QUIET, LOW, MED, HIGH CFM 177 / 283 / 417 / 494
SOUND RATING INDOOR dB-A 42 / 36 / 25 / 17
SOUND RATING OUTDOOR dB-A 51
OPERATING RANGE COOLING °F 14~118
OPERATING RANGE HEATING °F 14~75
EST. YEARLY OPERATING COST $ 77
ELECTRICAL DATA
POWER SOURCE V 208/230/60/1
MINIMUM AMPACITY A 10
COOLING WATTS W 857
HEATING WATTS W 960
MAX. TD FUSE/BREAKER A 15
POWER AND COMMUNICATION CABLE No. x AWG 4 x 18
REFRIGERATION SYSTEM
REFRIGERANT R410A
COMPRESSOR TYPE Twin Rotary
CONNECTIONS Flare
LIQUID LINE O.D. in 1/4
SUCTION LINE O.D. in 3/8
FACTORY PRECHARGE ft 25
REFRIGERANT CHARGE oz 44
MIN./MAX. LINE LENGTH ft 10~49
MAX. HEIGHT DIFFERENCE ft 23
DIMENSIONS & WEIGHT
INDOOR UNIT
W X H X D in 34-7/16 x 11-5/8 x 9-1/4
NET WEIGHT lbs 25
SHIPPING WEIGHT lbs 29
OUTDOOR UNIT
W X H X D in 34-5/16 x 25-7/8 x 12-5/8
NET WEIGHT lbs 95
SHIPPING WEIGHT lbs 100
TOTAL NET WEIGHT lbs 119
TOTAL SHIPPING WEIGHT lbs 128