Installation Manual 24-36YJ

13
ENGLISH
2
Unlock the tubing holder from the chassis
and mount between the chassis and instal-
lation plate in order to separate the bottom
side of the indoor unit from the wall.
* The feature can be changed according to the
type of model.
1
Raise the cover of terminal block.
2
Insert the connecting cable through the
bottom side of indoor unit and connect the
cable. (You can see detail contents in
‘Connecting the cables’ section.)
Tubing Holder
Control Cover
1(L1)
2(L2)
3
1(L) 2(N)
3
Power connecting cable
Piping
<Left side piping>
Connecting pipe
Connecting
cable
Ta pe
Drain hose
Drain hose
3 Tape the tubing pipe, drain hose and the
connection cable. Be sure that the drain
hose is located at the lowest side of the
bundle. Locating at the upper side can
cause overflow from the drain pan through
the inside of the unit.
* The feature can be changed according to
the type of model.
<Right side piping>
Connecting pipe
Connecting
cable
Tape
Drain hose
CAUTION
If the extension drain hose is routed inside
the room, insulate the hose with an insula-
tion material* so that dripping from sweat-
ing (condensation) could not damage fur-
niture or floors.
• Foamed polyethylene or equivalent is
recommended.
!
NOTE
!
Insert the drain hose at left side when you
use left side piping type.