Multi Zone Service Manual - General

Part 2 Functions & Controls
- 10 -
Only for training and service purposes
1. List of Functions & Controls
1.1 List of Function (Indoor)
Category Functions
USNW093B4B0[MW09Y3J]
USNW123B4B0[MW12Y3J]
ASNW183C4B0[MW18Y3J]
AMNW12GTRA0[MC12Y3JM]
AMNW18GTQA0[MC18Y3JM]
AMNW12GB1A0[MD12Y3JM]
AMNW18GB2A0[MD18Y3JM]
Air flow
Air supply outlet
1 4 1
Airflow direction control (left & right)
Auto X X
Airflow direction control (up & down)
Auto Auto X
Auto swing (left & right)
O X X
Auto swing (up & down)
O O X
Airflow steps (fan/cool/heat)
6 / 6 / 6 4 / 5 / 4 3 / 3 / 3
Chaos wind(auto wind)
O O X
Surge (cool/heat)
O / O O / X X / X
Swirl wind
X O X
Air purifying
Deodorizing filter
X X X
Plasma air purifier
X X X
Allergy Safe filter
X X X
Prefilter(washable / anti-fungus)
O O O
Installation
Drain pump
X O O
E.S.P. control*
X X O
Electric heater
X X X
High ceiling operation
X O X
Reliability
Hot start
O O O
Self diagnosis
O O O
Soft dry operation
O O O
Convenience
Auto changeover
X X X
Auto cleaning
O X X
Auto operation(artificial intelligence)
O O O
Auto Restart
O O O
Child lock*
O O O
Forced operation
O O X
Group control*
O O O
Sleep mode
O O X
Timer(on/off)
O O X
Timer(weekly)*
O O X
Two thermistor control*
O O O
Individual
controller
Wired remote controller PQRCVSL0QW[DWC1] PQRCVSL0QW[DWC1] PQRCVSL0QW[DWC1]
Deluxe wired remote controller
X X X
Simple wired remote controller
X X O
Simple Wired remote controller(for hotel use)
X X X
Wireless remote controller
O O X
Network
Solution
Dry contact
X X X
PI 485(for Indoor Unit)
X X X
Special func-
tion kit
Zone controller
X X X
CTI(Communication transfer interface)
X X X
Electronic thermostat
X X X
Others
Remote temperature sensor
X X X
Group control wire
X X X
Telecom shelter controller
X X X
Connector for water level sensor
O X X