Multi Zone Service Manual - General

5. Trouble Shooting
- 77 -
Only for training and service purposes
60
Inverter PCB & Main
EEPROM check sum error
EEPROM Access error
and Check SUM error
1. EEPROM contact defect/wrong insertion
2. Different EEPROM Version
3. ODU Inverter & Main PCB assembly damage
Display
code
Title Cause of error Check point & Normal condition
n Error Diagnosis and Countermeasure Flow Chart
Is EEPROM insertion normal?
No
Yes
Recheck power and installation condition
1.Check EEPROM insert direction/connection condition
2.Check EEPROM Check SUM
Replace if abnormality found
Is inverter PCB assembly normal?
No
Yes
Replace inverter PCB assembly
Yes
MAIN PCB assembly normal?
No
Replace MAIN PCB assembly
Check Point
- Check the EEPROM Check sum & Direction
<MAIN P
C
B>
<EEPR
O
M Direction
C
heck Point>