2014 Specialty Product Brochure

PERFORMANCE RATINGS Single Wall Mounted - H/P Inv
9k 12k 18k
SYSTEM MODEL NO. M09YJ M12YJ M18YJ
INDOOR MODEL MW09Y3J MW12Y3J MW18Y3J
OUTDOOR MODEL MR09Y3J MR12Y3J MR18Y3J
SPECIFICATIONS
CAPACITY COOLING (RATED) Btu 9,000 11,200 17,000
CAPACITY COOLING (MIN~MAX) Btu 3,070~12,620 3,070~14,660 3,070~20,470
CAPACITY HEATING
@
17
0
F (RATED) Btu 10,800 13,300 20,200
CAPACITY HEATING (MIN~MAX) Btu 3,070~17,060 3,070~20,470 3,070~30,700
COOLING AMPS 3 4.2 7
HEATING AMPS 3.7 4.9 7.8
SENSIBLE HEAT RATIO .88 .81 .78
SEER 21.5 21.5 18.0
EER 13.3 12.5 12.0
HSPF 11.0 11.0 9.7
ENERGY STAR YES YES YES
MOISTURE REMOVAL Pts/h 2.6 3.0 5.3
AIRFLOW (QUIET, LOW, MED, HIGH) CFM 124/212/272/335 124/212/272/335 300/399/509/622
SOUND RATING - INDOOR dB-A 19 / 24 / 33 / 38 19 / 24 / 33 / 39 29 / 35 / 40 / 45
SOUND RATING - OUTDOOR dB-A 45 45 53
OPERATING RANGE (COOLING)(WIND BAFFLE) °F 14(0)~118 14(0)~118 14(0)~118
OPERATING RANGE (HEATING) °F -4~75 -4~75 -4~75
EST. YEARLY OPERATING COST $ 61 81 127
ELECTRICAL DATA
POWER SOURCE V 208/230/60/1 208/230/60/1 230/208/60/1
MINIMUM AMPACITY A 10 10 19
COOLING WATTS W 677 896 1416
MAX. TD FUSE/BREAKER A 15 15 20
POWER AND COMMUNICATION CABLE
No. x AWG
4 x 18 4 x 18 4 x 18
REFRIGERATION SYSTEM
REFRIGERANT R410A R410A R410A
COMPRESSOR TYPE Inverter Inverter Inverter
CONNECTIONS Flare Flare Flare
LIQUID LINE O.D. in 1/4 1/4 1/4
SUCTION LINE O.D. in 3/8 3/8 1/2
FACTORY PRECHARGE ft 41 41 25
REFRIGERANT CHARGE oz 36 36 48
MIN./MAX. LINE LENGTH ft 7~66 7~66 10~66
MAX. HEIGHT DIFFERENCE ft 33 33 33
DIMENSIONS & WEIGHT
INDOOR UNIT
W X H X D in 35-1/4 x11-1/4 x8-1/4 35-1/4 x11-1/4 x8-1/4 40-5/8 x 12-7/8 x 9-5/8
NET WEIGHT lbs 23 23 31
SHIPPING WEIGHT lbs 27 27 36
OUTDOOR UNIT
W X H X D in 30-5/16x21-5/16x11-5/16 30-5/16x21-5/16x11-5/16 34-5/16x25-7/8x12-5/8
NET WEIGHT lbs 75 75 108
SHIPPING WEIGHT lbs 79 79 115
TOTAL NET WEIGHT lbs 98 98 139
TOTAL SHIPPING WEIGHT lbs 107 107 150
Your operating costs will depend on your utility rates and use. The estimated operating cost is based on a electricity cost of $ .115 per kWh.
For more information, visit www.ftc.gov/energy.
Due to continuing research in new energy-saving technology,
specications are subject to change without notice.
SPECIFICATIONS
12