SVC Manual (Exploded View) Model: M24YJ M30YJ M36YJ FAC P/no : 960-920-02
Product Specifications System 24k M24YJ MR24Y3J MW24Y3J kW 6.447 Cooling Capacity Btu/h. 22,000 kW 8.088 Heating Capacity Btu/h. 27,000 Power Input Cooling/Heating W 1760/2,380 Running Current Cooling/Heating A 7.9/10.7 Starting Current Cooling/Heating A 7.9/10.7 Cooling COP 3.66 EER 12.5 SEER 21.5 HSPF 11 Power Supply Ø/ V / Hz 1/208-230/60 Power Factor % 97 Indoor (QUIET, LOW, MED, HIGH) m3/min(CFM) 13(459)/15(530)/20(706)/24(848) Air Flow Rate 3 Outdoor,Max m /min(CFM) 60(2,119) Moisture Removal l/h. 2.
Piping Diagrams Model : M24YJ / M30YJ / M36YJ Indoor Unit Outdoor Unit Liquid Side EEV 2-Way Valve Th1 Th2 Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Th5 Th4 Gas Side 3-Way Valve Reversing Valve Accumulator Th3 Cooling Compressor Heating LOC.
Wiring Diagrams Indoor Unit Model : MW24Y3J / MW30Y3J / MW36Y3J CN-U/D CN-L/R CN-DISP3 CN-MOTOR1 CN-HVB CN-DISP1 CN-TH1 CN-TH2 CN-TH3 CN-REMO CN-CC CN-LINK 4
Outdoor Unit Model : MR24Y3J / MR30Y3J / MR36Y3J CN-TH2 CN-TH3 CN-PFC-OUT CN-PFC-IN CN-TH4 CN-4WAY CN-CENTRAL WCN-POWER WCN-W WCN-V WCN-U CN-EEV1 CN-MOTOR1 5 CN-COM
Exploded View Indoor Unit Model : MW24Y3J / MW30Y3J / MW36Y3J LOC 263230A 263230B Description Thermistor for suction air temperature Thermistor for evaporator middle temperature 6
Model : MW24Y3J MW24Y3J Loc.
Model : MW30Y3J MW30Y3J Loc No.
Model : MW36Y3J MW36Y3J Loc No.
Outdoor Unit Model: MR24Y3J / MR30Y3J / MR36Y3J LOC 263230A 263230B Description Thermistor for discharge pipe temperature Thermistor for outdoor air temperature Thermistor for condensing middle temperature 10
Model: MR24Y3J MR24Y3J Loc.
Model: MR30Y3J MR30Y3J Loc No.
Model: MR36Y3J MR36Y3J Loc No.