Models MWM18Y3J, MWM24Y3J, MRM18Y3J, MRM24Y3 Installation Manual

Table Of Contents
17
1.
There should be no obstruction near air inlet
and air outlet.
2.
Location should have acceptable condensate
disposal considerations.
3.
4.
Select a location which is out of reach for
children.
5.
Installed location should be rated for the
weight of equipment and not create
vibration or noise.
6.
The appliance must be installed 8 Ft
above floor.
Do not install directly above heat source or
electrical appliance.
Tools for installation
Selection of installation location
2. Screw driver
1. Level
4. Drill head
7. Open-end wrench
10. Vacuum pump
5. Pipe expander
8. Pipe cutter
11. Manifold gauges
3. Impact drill
6. Torque wrench
9. Leakage detector
12. Multimeter
13. Allen/spanner wrenches 14. Measuring tape
Note:
Please contact a local qualified installer for installation.
Ensure power cords are rated for use with equipment.
Basic requirement
Outdoor unit
Indoor unit
Installing the unit in the following
locations may cause operational issues
with equipment. If unavoidable seek
assistance from local dealer.
1.
Any location with an excessive heat
source, where flammables, gasses or
volitile flyings exist.
2.
Any location with high-frequency
devices (such as welding machine,
medical equipment).
3.Coastal locations.
4.
Corrosive or spaces that are excessivly
wet, such as pool rooms, laundry and
bath rooms.
1.
Be considerate of installed location due to hot airflow from unit and any noise that it
may create.
2.
Location should be well ventilated and dry, outdoor unit not to be exposed
directly to sunlight or strong wind.
3.
The location should be able to withstand the weight of outdoor unit.
4.
Ensure installation conforms to installation diagram.
5.
Select a location which is out of reach for children and far away from animals or
plants. If it is unavoidable, please add the fence for purpose of safety.