Service Manual MM09YJ-MM12YJ


Installation and Maintenance
6HUYLFH0DQXDO
6WHSV
3URFHGXUH
3RLQWV
5HPRYHHOHFWULFDOER[
Disconnect the Cable
clamp
a
Remove Temperature
Sensor; Disconnect the
connection wires.
Twist off the earthing screw
fixing the evaporator;
Pull out the all the wiring
terminals
b
Pay attention to the direction
of the retainer of the
thermistor so that the
retainer will not touch the
harness (same as the
existing models.)
Take care not to losw the clip
of thermistor
Terminal
board
Connecting
wires
Heat exchanger thermistor
Heat exchanger
thermistor
Remove a screw on the
electrical box.
c
Clip