SVC Manual (Exploded View) TYPE : WALL MOUNTED Applied Models : M09YJ M12YJ M09CJ M12CJ FAC P/no : 960-920-00
Product Specifications M09CJ M12CJ M09YJ M12YJ MR09C1J MR12C1J MR09Y3J MR12Y3J MW09C1J MW12C1J MW09Y3J MW12Y3J kW 0.89~2.638~3.70 0.89~3.106~4.30 0.89~2.638~3.70 0.89~3.282~4.30 Cooling Capacity Btu/h. 3,070~9,000~12,620 3,070~10,600~14,660 3,070~9,000~12,620 3,070~11,200~14,660 kW 0.89~3.165~3.70 0.89~3.898~4.30 Heating Capacity Btu/h. 3,070~10,800~17,060 3,070~13,300~20,470 Power Input Cooling W 677 815 677/700 896/1,000 Running Current Cooling A 6 7.3 3/3.7 4.2/4.9 Starting Current Cooling A 6 7.3 3/3.
2. Piping Diagrams Model : M09YJ / M12YJ Indoor Unit Outdoor Unit Liquid Side Th1 EEV 2-Way Valve Th2 Th4 Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Th3 Th7 Th6 Gas Side 3-Way Valve Reversing Valve Accumulator Th5 Cooling Compressor Heating LOC.
Model : M09CJ / M12CJ Indoor Unit Outdoor Unit Liquid Side EEV 2-Way Valve Th1 Heat Exchanger (Evaporator) Heat Exchanger (Condenser) Th2 Th5 Th4 Gas Side 3-Way Valve Accumulator Th3 Cooling Heating Compressor LOC.
3.
Indoor Unit Model : MW09C1J / MW12C1J CN-U/D CN-L/R CN-DISP3 CN-DISP1 CN-TH1 CN-TH2 CN-TH3 CN-CN-REMO CN-CC CN-MOTOR1 -6-
Safety Precautions Outdoor Unit Model : MR09Y3J / MR12Y3J CN-U(R) CN-V(S) CN-W(C) CN-EEV CN-TH1 CN-FAN(DC) CN-4WAY CN-HEATER CN-TH2 CN-COM CN-COIL1 WCN-P(L) CN-3 CN-COIL2 CN-E 7 WCN-P(N)
Outdoor Unit Model : MR09C1J / MR12C1J CN-U(R) CN-V(S) CN-W(C) CN-EEV CN-TH1 CN-FAN(DC) CN-TH2 CN-COM CN-COIL1 WCN-P(L) CN-3 CN-COIL2 CN-E 8 WCN-P(N)
Exploded View Indoor Unit Model: MW09Y3J / MW12Y3J 135316 135500B 152302A 131410 135313 733010 149303 149304 267110 342800 135500A 354210 135080 354212 359011 352150 346810 263230A 146811B 268711B 135500C 147582 W6640A 35211B 146811A W50400 749740 145200 268711D 249951 147581 135311 LOC 263230A 263230B 263230C Description Thermistor for suction air temperature Thermistor for evaporator inlet temperature Thermistor for evaporator outlet temperature Thermistor for evaporator middle tempera
Model: MW09Y3J MW09Y3J Loc No.
Model: MW12Y3J MW12Y3J L/N P/N_FRD Description Qty 131410 67601005 Chassis Assembly 1 149303 67602708 Holder,Tubing 1 346810 67603336 Motor Assembly,DC,Indoor 1 135500C 67601516 Cover 1 359011 67602121 Fan Assembly,Cross Flow 1 342800 67606700 Bearing 1 149304 67602709 Holder,Evaporator 1 354212 67602018 Evaporator Assembly,Final 1 354210 67602019 Evaporator Assembly,First 1 35211B 67605006 Tube Assembly,Tubing 1 249951 67600932 Case Assembly,Control(Indoor) 1
Indoor Unit Model: MW09C1J / MW12C1J 135316 135500B 152302A 131410 135313 733010 149303 149304 267110 342800 135500A 354210 135080 354212 359011 352150 346810 263230A 146811B 268711B 135500C 147582 W6640A 35211B 146811A W50400 749740 145200 268711D 249951 147581 135311 LOC.
Model: MW09C1J MW09C1J Loc No.
Model: MW12C1J MW12C1J Loc No.
Outdoor Unit Model: MR09Y3J / MR12Y3J LOC 263230A 263230B Description Thermistor for suction air temperature Thermistor for condenser inlet temperature Thermistor for condenser outlet temperature 15
Model: MR09Y3J MR09Y3J Loc No.
Model: MR12Y3J MR12Y3J Loc No.
Outdoor Unit Model: MR09C1J / MR12C1J LOC 263230A 263230B Description Thermistor for suction air temperature Thermistor for condenser inlet temperature Thermistor for condenser outlet temperature 18
Model: MR09C1J MR09C1J Loc No.
Model: MR12C1J MR12C1J Loc.
Friedrich Air Conditioning Co. I 10001 Reunion Place, Suite 500 I San Antonio, TX 78216 I 877.599.5665 www.friedrich.