Brochure

Multizone 48,000 BTU/h Eight Zone
System Pipe
Lengths
Total piping length (Outdoor to Indoor ) (Tp) (ft.) 476
Outdoor to Branch box (A, B)
Min. (ft.) 10
Max. (ft.) 180
Total branch piping length (Branch Box to indoor units) (A1-A3, B1-B4) (ft.) 295
Branch box to Indoor units
Min. (ft.) 10
Max. (ft.) 49
Max. Elevations
If outdoor unit is above or below indoor unit (E1) (ft.) 98
Between the farthest two indoor units (E3) (ft.) 49
Between branch distribution unit and farthest connected indoor unit(s) (E2) (ft.) 33
Between branch boxes (E4) (ft.) 49
REFRIGERATION LINE SETS MINIMUM/MAXIMUM LENGTHS
MULTIZONE | 48,000 BTU
(Tp)
A
B
E4
E1
E3
E2
BB unit
BB unit
A1
A2
A3
B1
B2
B3
B4
Y-Branch (DYBK)
BB unit
BB unit
SINGLE AND DUAL BB CONFIGURATIONS
Y - Branch DYBK
Branch Box D4PBB
Required for MR48K
33