Multi Zone Air Conditioner SVC MANUAL (Exploded View) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.
1. Specification Outdoor Spec. Nominal Input (Min~Rated~Max) Running Current Capacity(*) Cooling Heating Cooling Heating Cooling/Heating Starting Current Power Supply Power Supply Cable (outdoor) transmission cable (outdoor to indoor) Dimensions Net Weight Net Weight(Package) WxHxD MR24DY3JM Btu/h Class kW kW A A A Ø / V / Hz No. x AWG No. x AWG mm inch kg(lbs) kg(lbs) Type Qty x Model Compressor Motor Type Oil Charge volume cc Oil Type Charge (at 7.
2.
3. Piping Diagrams OUTDOOR UNIT Gas Side MAIN SVC V/V Reversing Valve Accumulator Low pressure S/W TH3 TH2 TH1 Heat Exchanger Compressor EEV-C Liquid Side EEV-B EEV-A TH4 MAIN SVC V/V COOLING HEATING Note: EEV: Electronic Expansion Valve LOC.
4.
Model Classification Description Part Number Location Number MR24DY3JM Heating EAD413446203 W6631 Compressor -6-
Model : MR24DY3JM Loc No.
Friedrich Air Conditioning Co. I 10001 Reunion Place, Suite 500 I San Antonio, TX 78216 I 877.599.5665 www.friedrich.