J SERIES DUCTLESS SPLIT SYSTEMS www.friedrich.
THE NEXT GENERATION OF DUCTLESS SPLIT SYSTEMS Advanced Inverter Ductless from Friedrich ENERGY STAR® MODELS ZERO DUCT LOSS Friedrich offers a wide variety of ENERGY STAR® models in both single and multizone configurations with SEERS up to 28.0 and EERs up to 16.1. The DOE reports that ducted systems lose an average of 25-40% in performance due to leaks, cracks or disconnections in ductwork. Many utility companies offer rebates on ductless systems. Contact your local energy provider or visit http://www.
Heat and cool up to 8 zones utilizing wall-mounted, ceiling cassette and The Insider™ concealed ducted models. Enjoy the flexibility to mix and match systems to fit your application. ZONE COOLING AND HEATING PROVIDES UNMATCHED CUSTOMIZED COMFORT AND ENERGY SAVINGS Occupants have the ability to set the temperature of each zone to their preferred comfort level*, or turn off units in unoccupied rooms without affecting other zones. That’s the beauty and efficiency of a Friedrich Multizone System.
The Advantages of Friedrich's Precision Inverter System Single or multizone, Friedrich ductless is superior to conventional systems Precision Inverter technology varies the compressor, the outdoor and the indoor fan speeds, eliminating constant compressor start-ups/shutdowns that traditional systems require to maintain the set temperature. Soft start technology starts the compressor with minimal amperage at start up, saving energy versus compressors utilzing locked rotor amperage (LRA).
No other system matches the efficiency and performance of Friedrich's Precision Inverter CONVENTIONAL SYSTEMS TWO-STAGE AIR CONDITIONERS Run at a single capacity, turning on and off to reach the desired set point. This means they run at full speed each time, resulting in high energy consumption. Won’t significantly reduce your energy use. These units only run at 2 speeds, 50% and 100%, also resulting in high energy consumption.
Attractive and high efficiency options for cooling and heating residential and light commercial spaces. Wall-mounted models mount high on an exterior wall. The attractive, neutral finish blends well with just about any decor. The units can be used individually or as part of a multizone system to condition multiple spaces or a large area.
Super High Efficiency and Zone Cooling Capability With Friedrich Ductless Split Systems, you can cool and heat single or multiple rooms more quietly and efficiently than window air conditioners or traditional central air systems, and without the expense of ductwork. You can control individual room temperatures, and heat or cool only the areas that are occupied.
Features you'll find with Friedrich Ductless Systems: Wall-mounted Single Zone Wall-mounted Multizone Cassette Single Zone Cassette Multizone The Insider™ Single Zone The Insider™ Multizone Wall Wall Ceiling Ceiling Ceiling Ceiling Cool only Y N N N N N Heat pump Y Y Y Y Y Y 115 volt cool only models Y N N N N N Inverter driven compressor Y Y Y Y Y Y Up to 28.0 Up to 22.0 Up to 19.0 Up to 22.0 Up to 17.6 Up to 18.
The indoor cross-flow fan and a low vibration compressor provide ultra quiet operation indoors and outdoors. Typical Window Air Conditioner ULTRA QUIET CROSS-FLOW FAN An electronically controlled cross-flow fan creates an ultra quiet, yet powerful air flow into the room. LOW VIBRATION, TWIN-ROTARY COMPRESSOR Friedrich's twin-rotary compressor has a unique design that reduces vibration for lower sound levels outdoors.
Convenient installation features that will get your ductless running in no time. A SET OF 16 INCH ON-CENTER HOLES UNIQUE MOUNTING BRACKET 16" ON-CENTER The hanging bracket comes with a set of holes that are placed 16” apart from each other to help you attach the bracket securely to "16 on center" wall studs. LEVEL-LINE LEDGES Incorporated “Level-Line Ledges” ensure a straight wall mount and frees both hands for an easy single-person installation.
OPTIONAL ACCESSORIES REFRIGERATION LINE SETS (REQUIRED ACCESSORY) Kit# Length Ft. Liquid Suction T32150 15’ 1/4” 3/8” T32350 35’ 1/4” 3/8” T42150 15’ 1/4” 1/2” T42350 35’ 1/4” 1/2” T53150 15’ 3/8” 5/8” T53350 35’ 3/8” 5/8” LOW AMBIENT WIND BAFFLE KIT* Wind baffle allows operation down to O°FWB on single zone heat pumps, and down to -4°FWB on Multizone units. *Models HM09YJA and HM12YJA operate down to O°FWB without a baffle kit.
COOL ONLY Single Zone Wall-mounted 9000-18000 Btu. Cool only models with features for convenient operation, care-free comfort and years of dependability.
SPECIFICATIONS PERFORMANCE RATINGS SYSTEM MODEL NO. INDOOR MODEL OUTDOOR MODEL SPECIFICATIONS CAPACITY COOLING (RATED) Btu CAPACITY COOLING (MIN~MAX) Btu COOLING AMPS SENSIBLE HEAT RATIO SEER EER ENERGY STAR MOISTURE REMOVAL Pts/h AIRFLOW (QUIET, LOW, MED, HIGH) CFM SOUND RATING - INDOOR dB-A SOUND RATING - OUTDOOR dB-A OPERATING RANGE ( 0°F WITH WIND BAFFLE) °FDB EST. YEARLY OPERATING COST $ ELECTRICAL DATA POWER SOURCE V MINIMUM AMPACITY A COOLING WATTS W MAX. TD FUSE/BREAKER A No.
HEAT PUMPS Single Zone Wall-mounted 9000 & 12000 Btu. Top cooling and heating performance in extreme climates. 28.0 SEER - our highest efficiencies ever! NEW! FEATURES • Precision Inverter® technology (variable speed compressor) SU PERIOR 28.
SPECIFICATIONS PERFORMANCE RATINGS SYSTEM MODEL NO. INDOOR MODEL OUTDOOR MODEL SPECIFICATIONS CAPACITY COOLING (RATED) CAPACITY COOLING (MIN~MAX) CAPACITY HEATING @470F (RATED) CAPACITY HEATING @170F (RATED) CAPACITY HEATING (MIN~MAX) COOLING AMPS HEATING AMPS SENSIBLE HEAT RATIO SEER EER HSPF ENERGY STAR MOISTURE REMOVAL AIRFLOW (QUIET, LOW, MED, HIGH) SOUND RATING - INDOOR SOUND RATING - OUTDOOR OPERATING RANGE (COOLING) OPERATING RANGE (HEATING) EST.
HEAT PUMPS Single Zone Wall-mounted 18000 - 36000 Btu. Features for comfort and convenience year 'round. In heating mode, units use approximately 1/4 of the energy required by electric heat.
SPECIFICATIONS PERFORMANCE RATINGS SYSTEM MODEL NO. INDOOR MODEL OUTDOOR MODEL SPECIFICATIONS CAPACITY COOLING (RATED) CAPACITY COOLING (MIN~MAX) CAPACITY HEATING @470 F (RATED) CAPACITY HEATING @170 F (RATED) CAPACITY HEATING (MIN~MAX) COOLING AMPS HEATING AMPS SENSIBLE HEAT RATIO SEER EER HSPF ENERGY STAR MOISTURE REMOVAL AIRFLOW (QUIET, LOW, MED, HIGH) SOUND RATING - INDOOR SOUND RATING - OUTDOOR OPERATING RANGE COOLING (WIND BAFFLE) OPERATING RANGE HEATING EST.
HEAT PUMPS Single Zone Ceiling Cassette 24000 and 36000 Btu. Indoor units are typically installed in a drop ceiling. The unit mounts flush to the ceiling for a clean look and efficient installation.
SPECIFICATIONS PERFORMANCE RATINGS Single Zone Cassette - Heat Pumps SYSTEM MODEL NO.
HEAT PUMPS Single Zone The Insider™ Concealed Ducted 24000 and 36000 Btu. Indoor unit is installed in the ceiling or furr down for unobtrusive installation.
SPECIFICATIONS PERFORMANCE RATINGS Single Zone - The Insider™ Concealed Ducted Heat Pumps 24k 36k D24YJ D36YJ MD24Y3J MR24UY3J MD36Y3J MR36UY3J 24,000 9,700~26,700 27,000 17,600 10,900~30,000 15.1 15.1 .68 17.0 12.0 10.0 No 7.0 530 / 618 / 688 38/36/35 62 5~118 -4~64 180 36,000 16,000~41,400 40,000 24,600 17,500~48,000 20.8 21.4 .67 17.6 12.1 9.2 No 10.6 706 / 953 / 1,130 39/38/37 67 5~118 -4~64 268 208/230/60/1 18.1 2000 30 4 x 14 208/230/60/1 24.
HEAT PUMPS Multizone Wall-mounted High efficiency heat pumps with features for comfort and convenience year 'round. In heating mode, units use approximately 1/4 of the energy required by electric heat.
SPECIFICATIONS PERFORMANCE RATINGS INDOOR MODEL SPECIFICATIONS CAPACITY COOLING (RATED) Btu CAPACITY HEATING (RATED) Btu MOISTURE REMOVAL Pts/h AIRFLOW (QUIET, LOW, MED, HIGH) CFM SOUND RATING - INDOOR dB-A ELECTRICAL DATA POWER SOURCE V, Ø, Hz REFRIGERATION SYSTEM CONNECTIONS LIQUID LINE O.D. in SUCTION LINE O.D.
HEAT PUMPS Multizone Ceiling Cassette Indoor units are typically installed in a drop ceiling. The grille fits almost flush with the ceiling for a clean look and efficient installation.
SPECIFICATIONS PERFORMANCE RATINGS INDOOR MODEL SPECIFICATIONS CAPACITY COOLING (RATED) CAPACITY HEATING (RATED) MOISTURE REMOVAL AIRFLOW ( LOW, MED, HIGH) SOUND RATING - INDOOR ELECTRICAL DATA POWER SOURCE POWER AND COMMUNICATION CABLE REFRIGERATION SYSTEM CONNECTIONS LIQUID LINE O.D. SUCTION LINE O.D.
HEAT PUMPS Multizone The Insider™ Concealed Ducted Indoor unit is installed in the ceiling or furr down for unobtrusive installation. Conditioned or non-conditioned air can be added to ducting to allow fresh air into the conditioned space whenever required.
SPECIFICATIONS PERFORMANCE RATINGS INDOOR MODEL SPECIFICATIONS CAPACITY COOLING (RATED) CAPACITY HEATING (RATED) MOISTURE REMOVAL AIRFLOW ( LOW, MED, HIGH) SOUND RATING - INDOOR ELECTRICAL DATA POWER SOURCE POWER AND COMMUNICATION CABLE REFRIGERATION SYSTEM CONNECTIONS LIQUID LINE O.D. SUCTION LINE O.D. DIMENSIONS & WEIGHT WXHXD NET WEIGHT SHIPPING WEIGHT Multizone - The Insider™ Concealed Ducted Heat Pumps 9k MD09Y3JM 12k MD12Y3JM 18k MD18Y3JM Btu Btu Pts/h CFM dB-A 9,000 10,400 2.
MULTIZONE CONFIGURATION GUIDELINES Mix-and-match a combination of indoor units that does not exceed the maximum connected capacity, and is within the recommended parameters: Wall-mounted Ceiling Cassette The Insider™ 7,000 9,000 12,000 18,000 12,000 18,000 MR24DY3JMA 33,000 Btu MAX. CONNECTED CAPACITY 9,000 12,000 18,000 MR36TQY3JMA MR48DEY3JM 48,000 Btu MAX. 65,000 Btu MAX.
MULTIZONE CONFIGURATIONS INDOOR SYSTEM COMPONENTS MODEL NUMBER Btu COOLING REVERSE CYCLE HEAT Btu VOLTAGE Rated Amps LINE SIZE DISCHARGE O.D. (IN.) LINE SIZE SUCTION O.D. (IN.) HEIGHT WIDTH DEPTH Wall-mounted Units MW07Y3JM 7000 8100 230 0.20 1/4" 3/8" 11-1/4” 34-7/8” 8-1/4” MW09Y3J 9000 10800 230 0.40 1/4" 3/8" 11-1/4" 35-1/4" 8-1/4" MW12Y3J 11200 13300 230 0.40 1/4" 3/8" 11-1/4" 35-1/4" 8-1/4" MW18Y3J 17000 20200 230 0.
REFRIGERATION LINE SETS MINIMUM/MAXIMUM LENGTHS SINGLE ZONE Single Zone System Model Outdoor Indoor Min. (ft.) Max. (ft.
REFRIGERATION LINE SETS MINIMUM/MAXIMUM LENGTHS MULTIZONE | 48,000 BTU Multizone 48,000 BTU/h Eight Zone (ft.) ≤476 Min. (ft.) 10 Max. (ft.) ≤180 (ft.) ≤295 (ft.) 10 Total piping length (Outdoor to Indoor ) (Tp) System Pipe Lengths Outdoor to Branch box (A, B) Total branch piping length (Branch Box to indoor units) (A1-A3, B1-B4) Min. Branch box to Indoor units Max. Elevations (ft.) ≤49 If outdoor unit is above or below indoor unit (E1) (ft.
OPTIONAL WIRED WALL CONTROLLER WIRED WALL CONTROLLER DWC2- Works with all Friedrich J Series ductless models except HM09Y3JA and HM12Y3JA PROGRAMMABLE SETTINGS • Simple program (1 to 7 hour) ON/OFF • 7 Day schedule • Sleep program • Holiday schedule • ON/OFF at set time WIRELESS DIAGNOSTIC TOOL FOR FRIEDRICH J SERIES* DUCTLESS SPLIT SYSTEMS Monitor and diagnose J Series Ductless Systems for quick service responses 3 EASY STEPS: Technician can observe various data points, such as: 1.