Installation and Operation Manual

19
How To Connect
IMPORTANT: Please read following electrical safety data carefully.
1. Remove front panel. See Figure 22.
2. Remove junction box.
Remove junction box cover by removing three screws from
front. Remove junction box by taking out top, rear and side
screws. See Figure 25.
FRP017
UNIT
CONNECTOR
JUNCTION BOX
JUNCTION BOX COVER
High
Med
Low
Fan
Cool
Heat
Fan Speed Mode
Temperature
Power
Figure 25
Junction Box Location
Figure 26
Power Connection
FRP018
ACCESSORY
POWER SUPPLY CORD
OR HARD WIRE
High
Med
Low
Fan
Cool
Heat
Fan Speed Mode
Temperature
Power
3. Connect accessory power supply cord or hard wire connector to
unit connector. See Figure 26.
Units must be installed using the appropriate power supply
kit. See Table 2 --POWER CONNECTION CHART. These
connections must be followed.
See Table 2 on page 14 for power cord accessory options and ratings.
4. Reinstall junction box and cover.
Use wire clamp to attach power cord to basepan. Secure
with screws (included) See Figure 27.
Replace junction box and cover with screws removed from
Step 2. Tighten securely.
5. Replace front panel. See Figure 24.
6. Connect power to unit.
Figure 27
Wire Clamp
FRP019
WIRE CLAMP
High
Med
Low
Fan
Cool
Heat
Fan Speed Mode
Temperature
Power