Service and Parts Manual (2018, 2019, 2020, 2021, 2022)
Table Of Contents
- INTRODUCTION
- Important Safety Information
- Personal Injury Or Death Hazards
- Operation of Equipment in During Construction
- Model Number Reference Guide
- Serial Number Reference Guide
- Product Features
- General Specifications 7-9k Electric Heat
- General Specifications 7-9k Heat Pump Models
- General Specifications 12-15k Electric Heat
- General Specifications 12-15k Heat Pump
- Electrical Data
- Function and Control
- Refrigeration Sequence Of Operation
- Refrigerant System Diagram
- PTAC Installation Recommendations
- Wall Sleeve Installation Instructions (PDXWS)
- Alternate Wall Installations
- PXDR10 Drain Kit Installation
- External Drain
- PXGA Standard Grille
- Chassis Install Preparation
- Chassis Installation
- How To Connect
- Install WRT2 Wireless Programmable Thermostat
- Final Inspection & Start-up Checklist
- Refrigerant Charging
- Undercharged Refrigerant Systems
- Overcharged Refrigerant Systems
- Restricted Refrigerant System
- Sealed System Method of Charging/ Repairs
- Hermetic Components Check
- Reversing Valve Description And Operation
- Testing The Reversing Valve Solenoid Coil
- Checking The Reversing Valve
- Touch Test Chart : To Service Reversing Valves
- Compressor Checks
- Compressor Replacement -Special Procedure in Case of Compressor Burnout
- Basic Troubleshooting
- Malfunction Analysis
- Unit Lost Power
- Control Panel Does Not Work
- Malfunction of Temperature Sensor
- E4 Function Error
- E8 Function Error
- E9 Function Error
- Electric Heater Not Running
- Electric Heater Not Running
- 7K Cool+ Electric Heat 230 V
- 9K Cool+ Electric Heat 230v and 265v
- 12K Cool+ Electric Heat 230v and 265v
- 15K Cool+ Electric Heat 230v
- 7K Cool+ Heat Pump 230v
- 9K Cool+ Heat Pump 230v and 265v
- 12K Cool+ Heat Pump 230v and 265v
- 15K Cool+ Heat Pump 230v
- PZE07K3SB,PZE09K3SB, PZE09R3SB, PZE12K3SB, PZE12R3SB, PZE15K3SB
- PZH07K3SB, PZH09K3SB, PZH09R3SB, PZH12K3SB, PZH12R3SB, PZH15K5SB
- Reference Sheet of Celsius and Fahrenheit
- Resistance Table of THERMISTORS (5K)
13 PB
SPECIFICATIONS
General Specications 7-9k Heat Pump Models
PTAC Heat Pump models
PZH07K PZH09R PZH09R
PERFORMANCE DATA:
Cooling Btu 7200/6800 9600/9400 9200
Cooling Watts 600/565 815/800 800
Energy Efcient Ratio, Eer 12.0/12.0 11.8/11.8 11.5
Reverse Heating Btu 6400/6300 8500/8200 8500
Heating Watts 530/520 710/685 710
Cop 3.55/3.54 3.51/3.51 3.51
Moisture Removal (Pints/Hr.) 0.7 1.2 1.6
Sensible Heat Ratio 0.87 0.82 0.82
ELECTRICAL DATA:
Voltage(1 PHASE, 60 Hz) 230/208 230/208 265
Volt Range 253-187 253-187 292-239
Current (Amps) 2.6/2.7 3.5/3.8 4.2
Reverse Heat. Amps 2.3/2.5 3.0/3.3 2.7
Power Factor 0.99 0.99 0.99
Compressor LRA 13.0 20.0 18.2
Compressor RLA 2.5 3.3 3.1
Outdoor Fan Motor, HP 0.07 0.07 0.1
AIRFLOW DATA:
Indoor CFM, HIGH 335 400 400
Indoor CFM, LOW 250 250 290
VENT CFM 75 75 75
PHYSICAL DATA
Sleeve Dimensions (H x W x D) 16” x 42” x 13 3/4” (all models)
Dimensions with Front (H x W x D) 16”x 42”x 21 1/2” (all models)
Cut Out Dimensions (H x W x D) 16 1/4”x 42 1/4” (all models)
Net Weight (lbs.) 105 109 113
Shipping Weight (lbs.) 127 131 136
R-410A CHARGE (oz.) 30.0 32.1 31.4
Dimensions with Packaging (inches) 17 7/8" x 45" x 25 1/4" (all models)
Figure 202 (General Specs)