Service and Parts Manual (2018, 2019, 2020, 2021, 2022)
Table Of Contents
- INTRODUCTION
- Important Safety Information
- Personal Injury Or Death Hazards
- Operation of Equipment in During Construction
- Model Number Reference Guide
- Serial Number Reference Guide
- Product Features
- General Specifications 7-9k Electric Heat
- General Specifications 7-9k Heat Pump Models
- General Specifications 12-15k Electric Heat
- General Specifications 12-15k Heat Pump
- Electrical Data
- Function and Control
- Refrigeration Sequence Of Operation
- Refrigerant System Diagram
- PTAC Installation Recommendations
- Wall Sleeve Installation Instructions (PDXWS)
- Alternate Wall Installations
- PXDR10 Drain Kit Installation
- External Drain
- PXGA Standard Grille
- Chassis Install Preparation
- Chassis Installation
- How To Connect
- Install WRT2 Wireless Programmable Thermostat
- Final Inspection & Start-up Checklist
- Refrigerant Charging
- Undercharged Refrigerant Systems
- Overcharged Refrigerant Systems
- Restricted Refrigerant System
- Sealed System Method of Charging/ Repairs
- Hermetic Components Check
- Reversing Valve Description And Operation
- Testing The Reversing Valve Solenoid Coil
- Checking The Reversing Valve
- Touch Test Chart : To Service Reversing Valves
- Compressor Checks
- Compressor Replacement -Special Procedure in Case of Compressor Burnout
- Basic Troubleshooting
- Malfunction Analysis
- Unit Lost Power
- Control Panel Does Not Work
- Malfunction of Temperature Sensor
- E4 Function Error
- E8 Function Error
- E9 Function Error
- Electric Heater Not Running
- Electric Heater Not Running
- 7K Cool+ Electric Heat 230 V
- 9K Cool+ Electric Heat 230v and 265v
- 12K Cool+ Electric Heat 230v and 265v
- 15K Cool+ Electric Heat 230v
- 7K Cool+ Heat Pump 230v
- 9K Cool+ Heat Pump 230v and 265v
- 12K Cool+ Heat Pump 230v and 265v
- 15K Cool+ Heat Pump 230v
- PZE07K3SB,PZE09K3SB, PZE09R3SB, PZE12K3SB, PZE12R3SB, PZE15K3SB
- PZH07K3SB, PZH09K3SB, PZH09R3SB, PZH12K3SB, PZH12R3SB, PZH15K5SB
- Reference Sheet of Celsius and Fahrenheit
- Resistance Table of THERMISTORS (5K)
20 PB
OPERATION
Function and Control
Buttons and Display
1) Buttons
There are ON/OFF, UP, DOWN, HEAT, COOL, CONSTANT FAN and fan speed of HIGH, LOW, AUTO buttons.
1. ON/OFF: Press to turn power on or off to the unit.
2. COOL, HEAT: choose the mode of operation
3. HIGH, LOW, AUTO: choose the fan speed.
4. UP, DOWN: Adjust the setting temperature , default: 60-90°F(16~32°F).
2) Dual 8 Digital Tube Displayer and LED
Two 8 digital tube and 7 LEDs (ON/OFF, HIGH, LOW, AUTO, HEAT, COOL, CONSTANT FAN)
1. Mode LED display: when the unit is running in a certain mode, the corresponding LED is lit up.
2. ON/OFF LED: at ON status, the LED is lit up.
3. CONSTANT FAN LED: when this function is enabled, the LED is lit up.
4. Fan speed LED: when the unit is running at HIGH, LOW or AUTO fan speed, the corresponding LED is lit up.
5. Dual 8 digital tube displayer: normally, it displays the indoor ambient temperature. When the UP/DOWN
button is pressed it displays the setting temperature. If an error occurs, it displays the ERROR.
CODE (See table below).
The LED close to the button indicates the current status (lit up means effective).
ERROR CODE TABLE:
"E2" Indoor ambient temp sensor is open circuit or short circuit
"E3" Indoor pipe temp sensor is open circuit or short circuit
"E4" 1.Indoor vent outlet temp sensor is open circuit or short
circuit
2.Outlet air overheat in Electric heating mode
"E5" Outdoor pipe temp sensor is open circuit or short circuit
"E8" 1.Frost protection in cooling
2.Indoor pipe overheat protection in heat pump"
"E9" High pressure protection
Temperature Parameter
Indoor setting temperature (Ts)
Indoor ambient temperature (T1)
System Basic Function
Once the compressor starts, the compressor won’t stop with the change of the indoor temperature. Once the
compressor stops, it can only start after a 3 mins delay. (The compressor can stop immediately at the time of mode
switchover, turning off the unit, adjusting setting temperature and turning off from a function error.)
1) Cooling Mode
Working conditions and process for cooling:
When T1≥Ts+2°F(1°C), the unit is running in cooling mode. Meanwhile, the compressor is running and the fan is
running at the setting fan speed;
When T1≤Ts-2°F(1°C), the compressor is OFF. Meanwhile, the fan will run at the setting fan speed for 15s (CONSTANT
FAN OFF); or run at the setting speed continuously (CONSTANT FAN ON);
When Ts-2 2°F(1°C)<T1<Ts+ 2°F(1°C), the unit keeps previous running status.