Service and Parts Manual (2018, 2019, 2020, 2021, 2022)
Table Of Contents
- INTRODUCTION
- Important Safety Information
- Personal Injury Or Death Hazards
- Operation of Equipment in During Construction
- Model Number Reference Guide
- Serial Number Reference Guide
- Product Features
- General Specifications 7-9k Electric Heat
- General Specifications 7-9k Heat Pump Models
- General Specifications 12-15k Electric Heat
- General Specifications 12-15k Heat Pump
- Electrical Data
- Function and Control
- Refrigeration Sequence Of Operation
- Refrigerant System Diagram
- PTAC Installation Recommendations
- Wall Sleeve Installation Instructions (PDXWS)
- Alternate Wall Installations
- PXDR10 Drain Kit Installation
- External Drain
- PXGA Standard Grille
- Chassis Install Preparation
- Chassis Installation
- How To Connect
- Install WRT2 Wireless Programmable Thermostat
- Final Inspection & Start-up Checklist
- Refrigerant Charging
- Undercharged Refrigerant Systems
- Overcharged Refrigerant Systems
- Restricted Refrigerant System
- Sealed System Method of Charging/ Repairs
- Hermetic Components Check
- Reversing Valve Description And Operation
- Testing The Reversing Valve Solenoid Coil
- Checking The Reversing Valve
- Touch Test Chart : To Service Reversing Valves
- Compressor Checks
- Compressor Replacement -Special Procedure in Case of Compressor Burnout
- Basic Troubleshooting
- Malfunction Analysis
- Unit Lost Power
- Control Panel Does Not Work
- Malfunction of Temperature Sensor
- E4 Function Error
- E8 Function Error
- E9 Function Error
- Electric Heater Not Running
- Electric Heater Not Running
- 7K Cool+ Electric Heat 230 V
- 9K Cool+ Electric Heat 230v and 265v
- 12K Cool+ Electric Heat 230v and 265v
- 15K Cool+ Electric Heat 230v
- 7K Cool+ Heat Pump 230v
- 9K Cool+ Heat Pump 230v and 265v
- 12K Cool+ Heat Pump 230v and 265v
- 15K Cool+ Heat Pump 230v
- PZE07K3SB,PZE09K3SB, PZE09R3SB, PZE12K3SB, PZE12R3SB, PZE15K3SB
- PZH07K3SB, PZH09K3SB, PZH09R3SB, PZH12K3SB, PZH12R3SB, PZH15K5SB
- Reference Sheet of Celsius and Fahrenheit
- Resistance Table of THERMISTORS (5K)
46 PB
INSTALLATION
Install WRT2 Wireless Programmable Thermostat
INSTALLER SETTINGS
HOW TO ENTER
• Set thermostat to OFF mode
• Hold UP + FAN for 5 seconds
HOW TO NAVIGATE
• Press UP or DOWN to change setting value
• Press MODE to save setting value and proceed to next setting option
• Press FAN to return to previous setting option
HOW TO EXIT
• Press MODE until last setting page (99) has been saved or leave thermostat with no button pressfor 60 seconds
• Note: You must press MODE to save each setting value
Menu Number Function Description User Option Number Default setting
01 Temperature Scale F: Fahrenheit C: Celsius F
02 Temperature Calibration +/- 5.4°F 0.0°F
03 Available modes "01 : Heat and Cool with auto
02 : Heat and Cool without auto 03 : Heat only
04 : Cool only"
01
04 Max Heat Set Temp F: 60 to 90 (5°F step) 80°F
05 Min Cool Set Temp F: 60 to 80 (5°F step) 65°F
06 PTAC Type H-C: Heat-Cool HP: Heat Pump H-C
07 HP valve type B: B Valve O: O Valve B
08 Auto dead-band between heat and cool operation
in AUTO mode
2 to 5°F (1°F step) 4°F
09 Stage 1 Temperature Control Swing "±0.25°F
±0.50°F
±1.00°F
±2.25°F"
0.50°F
10 Auxiliary Stage Cut-In Offset (only used for HP
system type)
"OFF (No Electric / Auxiliary heat)
-3.0 to -8.0°F (1°F step)"
-4.0°F
12 High FAN availability ON: High fan available OFF: High fan not available ON
13 Programming mode "OFF: Manual
ON: Programmable"
OFF
20 Default cool mode set temperature (manual mode
only)
Min Cool Set Temp to 80°F 74°F
21 Start RF Pairing "NO: no action
YES: start RF pairing
DEL: delete the current receiver INFO: show RF status for receiver"
NO
14 Clock Format (Programming mode only) "12 : 12 hour
24 : 24 hour"
12
15 Periods per day (Programming mode only) "4: 4 periods per day
2: 2 periods per day
1: 1 period per day"
2
16 Auto Daylight Savings (Programming mode only) ON: Auto DST on OFF: Auto DST off ON
17 (Not Used)
18 Reset to default set temperatures after each mode
change (manual mode only)
"ON: uses default temperatures after each mode change (see menu
19 and 20)
OFF: Maintain last set temperature for each mode"
ON
19 Default heat mode set temperature (manual mode
only)
60°F to Max Heat Set Temp 70°F
98 Minimum off time - Compressor protection "NO: Immediate off/ on switching
YES: 3-minute minimum off time enforced"
NO
99 Reset "NO: no reset
YES: ex-factory reset"
NO