PRODUCT PROFILE ZoneAire Select ® Packaged Terminal Air Conditioners Features • Tangential blower wheel for fast, powerful and even air distribution • Two permanentlylubricated fan motors for quiet operation • EERs up to 12.0; COPs up to 3.
PRODUCT FEATURES 2 DIGITAL TEMPERATURE READOUT By digitally monitoring the desired room temperature, the room is controlled more precisely than conventional systems. The large, easy-to-read LED display can show either the setpoint or actual room temperature as selected by owner. ONE-TOUCH OPERATION When the unit is powered off, the unit can be returned directly to heating or cooling mode by pressing the ‘Heat’ or ‘Cool’ buttons without the confusing power up sequence of some controls.
PRODUCT FEATURES DIGITAL DEFROST THERMOSTAT The PZ-Series uses a digital thermostat to accurately monitor the outdoor coil conditions to allow the heat pump to run whenever conditions are correct. Running the PTAC in heat pump mode saves energy and reduces operating costs. The digital thermostat allows maximization of heat pump run time.
CHASSIS SPECIFICATIONS PZE Series with Electric Heat Model PERFORMANCE DATA: Cooling Btu Cooling Watts Energy Efficient Ratio, EER Heater Size (kW) Moisture Removal (pints/hr.
COOLING & HEATING PERFORMANCE PZE 230V - Extended Cooling Performance OUTDOOR DRY BULB TEMP. (DEGREES F AT 40% R.H.) 85 95 105 75 110 INDOOR WET BULB TEMP. (DEGREES F AT 80 F D.B.) PZE07 PZE09 PZE12 PZE15 Btu WATTS AMPS SHR Btu WATTS AMPS SHR Btu WATTS AMPS SHR Btu WATTS AMPS SHR 72 9055 522 2.3 0.53 10584 653 3.1 0.49 14112 914 4.2 0.49 17640 1248 5.5 0.47 67 8709 531 2.3 0.72 10179 663 3.1 0.66 13572 928 4.2 0.66 16965 1268 5.6 0.63 62 8062 536 2.4 0.96 9423 670 3.1 0.89 12564 939 4.3 0.
COOLING & HEATING PERFORMANCE PZE 265V - Extended Cooling Performance OUTDOOR DRY BULB TEMP. (DEGREES F AT 40% R.H.) 75 85 95 105 110 INDOOR WET BULB TEMP. (DEGREES F AT 80 F D.B.) Btu PZE09 PZE12 72 67 62 72 67 62 72 67 62 72 67 62 72 67 62 10584 10179 9423 10080 9504 8766 9684 9000 7965 9072 8055 7101 8073 6948 6138 947 WATTS 653 663 670 711 718 727 800 800 800 865 864 866 943 943 AMPS 3.1 3.1 3.1 3.3 3.3 3.3 3.7 3.7 3.7 4.0 4.0 4.0 4.3 4.
ELECTRIC HEAT DATA PZE/ PZH09K PZE/ PZH09R HEATER WATTS 3600 2940 3600 VOLTAGE 230 208 265 HEATING BTU 8500 8200 8500 HEATING CURRENT (AMPS) 15.9 14.3 13.7 MINIMUM CIRCUIT AMPACITY 19.9 17.9 17.1 BRANCH CIRCUIT FUSE (AMPS) 20 20 20 PZE/ PZH12K PZE/ PZH12R HEATER WATTS 3600 2940 3600 VOLTAGE 230 208 265 HEATING BTU 11000 10800 11000 HEATING CURRENT (AMPS) 15.9 14.3 13.7 MINIMUM CIRCUIT AMPACITY 19.9 17.9 17.
MODEL IDENTIFICATION / COMPONENTS PTAC/PTHP Model Identification Guide PZ H 07 K 3 S A Series PZ = Friedrich Digital PTAC System E = Cooling with or without electric heat H = Heat Pump with auxiliary heat Design Series Chassis S = Standard NOMINAL CAPACITY 07 = 7,000 Btu 09 = 9,000 Btu 12 = 12,000 Btu 15 = 15,000 Btu Nominal Heater Size (@ 230V or 265V) 3 = 3.6KW (7K/9K/12K models) VOLTAGE K = 230/208V - 1 Ph. - 60 Hz. R = 265V - 1 Ph. - 60 Hz. 5 = 5.0 KW* (15K models) * 5.
ZoneAire® Select Series PTAC Cooling with Electric Heat, Heat Pump PURCHASER P.O.
INSTALLATION Typical Wall Sleeve Installation (PDXWSA) ELECTRICAL RECEPTACLE PDXWSA Wall Sleeve Dimensions: 16" H x 42" W x 13 3/4" D 42-¼" MIN. LINTEL TO SUPPORT MASONRY WALLS 16-¼" 60" MAX. Front Cover Dimensions: 16" H x 42" W x 7 3/4" D Cut-Out Dimensions: 16 1/4" x 42 1/4" 20" MAX.
ACCESSORY INSTALLATION Internal Drain Kit Location and Installation (PXDR10) SCREW WALL SLEEVE OPTIONAL AREA GASKET PREFERRED AREANO FOAM INSULATION MOUNTING PLATE DRAIN TUBE NUT SIDE VIEW IF THE DRAIN MUST BE LOCATED IN THE OPTIONAL AREA, THE FOAM INSULATION MUST BE CUT AWAY AND REMOVED TO ALLOW ACCESS TO THE DRAIN.
HVAC Engineering Specifications Digital Packaged Terminal Air Conditioners & Heat Pumps Cooling: 7200 – 14500 Btu Heating: 6400 – 13600 Btu (Heat Pump) 6824 – 17060 Btu (Electric Heat) Friedrich Models: PZE – Cooling with electric heat PZH – Heat Pump with electric heat All units shall be factory assembled, piped, wired and fully charged with R-410A. All units shall be certified in accordance with ARI Standard 310 for air conditioners and ARI standard 380 for heat pumps.
ACCESSORIES New Construction Accessories PDXWSA WALL SLEEVE Galvanized zinc coated steel is prepared in an 11step process, then powder coated with a polyester finish and cured in an oven for exceptional durability. The wall sleeve is insulated for sound absorption and thermal efficiency, 16" H x 42" W x 13 3/4" D. PDXWSEXT18 DEEP WALL SLEEVE For walls up to 17 1/2" deep. PDXWSEXT24 DEEP WALL SLEEVE For walls up to 23 1/2" deep.
ACCESSORIES New Construction Accessories PDXDAA LATERAL DUCT ADAPTER Attaches to the Friedrich PTAC/PTHP unit to direct up to 35% of the total airflow to a second room. The unit-mounted duct plenum features a front-mounted aluminum grille that has two positions to provide the most optimal air direction. The air may be directed to either the left or the right of the unit through the supplied 3 1/2" H x 7" W x 47" L plenum. Plenum may be cut to length by the installer.
THIS PAGE INTENTIONALLY LEFT BLANK.
Friedrich Air Conditioning Co. 10001 Reunion Place, San Antonio, TX 78216 800.541.6645 www.friedrich.com ZONEAIRE® • SELECT SERIES PACKAGED TERMINAL AIR CONDITIONERS LIMITED WARRANTY SAVE THIS CERTIFICATE. It gives you specific rights. You may also have other rights which may vary from state to state and province to province In the event that your unit needs servicing, contact your nearest authorized service center.