Submittal (2021)

ZoneAire
®
Select Series
PTACs
COOLING WITH ELECTRIC HEAT, HEAT PUMPS
PTAC ZoneAire Select Series Submittal 2021_2-24-21
PURCHASER P.O. # DATE
PROJECT LOCATION
ENGINEER ARCHITECT
SUBMITTED BY FOR APPROVAL FOR REFERENCE
ITEM PLAN DESIGNATION QUANTITY COOLING Btu VOLTAGE FRIEDRICH MODEL
PDXWSA Wall Sleeve Qty
PDXWSEXT18
Deep Wall Sleeve- For walls up to
17" deep
Qty
PDXWSEXT24
Deep Wall Sleeve- For walls up to
23
1
/2" deep
Qty
PDXWSEXT
Custom Deep Wall Sleeve, For
walls from 13
1
/4" to 25
1
/2" deep
Qty
PXGA Standard Outdoor Louver Qty
PXAA Architectural Louver, clear Qty
PXBG Architectural Louver, beige Qty
PXSC Architectural Louver, color matched Qty
PDXRTA Remote Thermostat Escutcheon Kit Qty
PXDR10 Condensate Drain Kit (pkg/10) Qty
PXSBA Sub Base Qty
PXCJA Conduit Kit w/ Junction Box Qty
PDXDAA Lateral Duct Adapter Qty
PDXDEA Lateral Duct Extension Qty
PXDS Sub Base Disconnect Switch Qty
Accessories
PXSB23020 Electrical Subbase - 230V 15A and 20A Qty
PXSB23030 Electrical Subbase - 230V 30A Qty
PXSB26515 Electrical Subbase - 265V 15A Qty
PXSB26520 Electrical Subbase - 265V 20A Qty
PXSB26530 Electrical Subbase - 265V 30A Qty
RT7
Wired Digital Thermostat
Qty
RT7P
Wireless Digital Thermostat
Qty.
WRT2
Wireless Digital Thermostat
Qty
EMRT2
Wired Thermostat with Occupancy Sensor
Qty
EMWRT2
Wireless Thermostat with Occupancy Sensor
Qty
EMOCT
Online Connection Kit
Qty
EMRAF
Remote Access Fee
Qty
EMRHCF
Energy Management Remote
Humidity Control Fee
Qty
PXFTA Replacement Filters (Set of 10) Qty.
UVT1
UV FreshAire Light
Qty.
APWM1
iWave FreshAire Purication
Qty.
Features
Constant room comfort monitoring
“Instant Heat” heat pump mode quickly
heats a room to the desired temperature for
increased comfort
Even heat monitoring checks room
temperature and automatically adds heat
boost if necessary
Room freeze protection- heat initiated if
temperature falls to 40°F in an unoccupied
room, raising temperature to 46°F
Dual motors for quiet operation
Durable, powder coat paint nish
Indoor coil frost sensor protects the
compressor to lengthen the life of the unit.
Random compressor restart protects
electrical systems from overload when
power is restored
Separate heat and cool range limits
Desk control ready allowing hotel owners
to control units from a central location
Condensate removal system uses slinger
ring technology
Electronic defrost control ensures more run
time in the efcient heat pump mode
Fresh air damper control to bring in fresh
outside air when desired
Washable, antimicrobial air lter
Service error code memory storage
Emergency heat override
FreshAire
®
IAQ ready